Gabatarwa

Lokacin sayen na'urar canza wutar lantarki (transformer), ƙayyadaddun bayanai na fasaha suna bayyana wani ɓangare ne kawai na labarin. Tabbacin inganci yana cikin rahotannin gwaji da alamun takaddun shaida. Ga ƙwararrun masu sayayya waɗanda ke kewaya kasuwannin duniya, fahimtar ma'anar waɗannan gwaje-gwajen da kuma waɗanne takaddun shaida ne ke da mahimmanci na iya nufin bambanci tsakanin saka hannun jari mai inganci da kuskure mai tsada.

Wannan labarin ya ba da taƙaitaccen jagora game da gwajin transformer da takaddun shaida—waɗanne gwaje-gwaje ake yi, yadda suka bambanta, da kuma waɗanne takaddun shaida na ƙasashen duniya ya kamata ku nema.

Kashi na Ɗaya: Gwaje-gwajen da Aka saba yi da Gwaje-gwajen Nau'i—Sanin Bambancin

Gwaje-gwajen na'urar canza wutar lantarki sun kasu kashi biyu, kowannensu yana da manufa ta musamman.

Gwaje-gwaje na yau da kullunAna gudanar da aikin a kan kowace na'urar transfoma kafin ta bar masana'anta. Suna tabbatar da cewa na'urar ba ta da lahani a masana'anta kuma tana aiki kamar yadda aka tsara. Manyan gwaje-gwajen yau da kullun sun haɗa da:

  • Ma'aunin juriya mai jurewa
  • Ratio na ƙarfin lantarki da tabbatar da ƙaura lokaci
  • Rashin asarar kaya da ma'aunin yanzu
  • Asarar kaya da ma'aunin juriya na ɗan gajeren lokaci
  • Gwaje-gwajen Dielectric (jure mitar wutar lantarki)
  • Ma'aunin juriyar rufi

 

Gwaje-gwajen nau'iAna yin su ne a kan wani sashi na ƙira don tabbatar da injiniyan kanta. Waɗannan cikakkun bayanai ne kuma masu amfani da albarkatu, ana yin su sau ɗaya kawai a kowane ƙira sai dai idan an yi manyan canje-canje. Sun haɗa da:

  • Gwajin hauhawar zafin jiki
  • Gwajin bugun walƙiya
  • Ma'aunin matakin sauti

Gwaje-gwaje na musammanƙarin gwaje-gwaje ne da aka amince da su tsakanin masana'anta da mai siye don takamaiman aikace-aikace - auna fitarwa na ɗan lokaci, gwajin juriya na ɗan gajeren lokaci, ko nazarin amsawar mita don gano motsi na tsakiya.

Kashi na Biyu: Manyan Takaddun Shaida na Ƙasashen Duniya

Kasuwa daban-daban suna buƙatar takaddun shaida daban-daban. Fahimtar waɗannan buƙatu yana da mahimmanci don samun damar kasuwa.

Tarayyar Turai.Alamar CE wajibi ne, wanda ke nuna bin ƙa'idodin EU masu dacewa. Dole ne kayayyaki su cika buƙatun ingancin Ecodesign.

Amirka ta Arewa.Takaddun shaida na UL shine ma'aunin aminci da aka amince da shi ga kasuwar Amurka, yayin da ake buƙatar takardar shaidar CSA ga Kanada. Dukansu sun haɗa da gwaji mai tsauri da kuma duba masana'anta.

Tsarin Duniya.Tsarin CB na IECEE yana ba da fahimtar rahotannin gwaji tsakanin ƙasashe masu shiga. Rahoton gwajin CB guda ɗaya zai iya sauƙaƙe amincewa a cikin kasuwanni da yawa - musamman ma masu mahimmanci ga masana'antun da ke hidimar yankuna daban-daban.

Gabas ta Tsakiya.Takaddun shaida na SASO wajibi ne ga Saudiyya, wanda galibi yana buƙatar ƙarin gwaji don yanayin zafi mai yawa (55°C).

Kudu maso Gabashin Asiya.Kasuwa kamar Indonesia suna buƙatar takardar shaidar SNI; Thailand tana buƙatar TISI. Sau da yawa kayayyaki suna buƙatar kariyar IP54 ko fiye don yanayin zafi.

Kashi na Uku: Abin da za a nema a cikin Rahoton Gwaji

Rahoton gwaji ya ƙunshi fiye da sakamakon cin nasara/faɗuwa. Sanin abin da za a bincika yana taimakawa wajen tabbatar da inganci.

Don gwaje-gwajen rabon juyawa,kwatanta ƙimar da aka auna da ƙayyadaddun bayanai na asali. Bambanci tsakanin kashi 0.5 cikin ɗari abu ne na yau da kullun; manyan bambance-bambance na iya nuna matsalolin juyawa.

Don juriya ga rufi,ƙima ya kamata ya wuce 100 MΩ ga matsakaici-Masu Canza Wutar LantarkiKaratun da ke ƙasa da MΩ 10 yana buƙatar bincike.

Don gwaje-gwajen dielectric,tabbatar da cewa ƙarfin lantarki da aka yi amfani da shi ya cika buƙatun IEC 60076-3 kuma babu wani rugujewa da ya faru yayin gwaji.

Koyaushe duba:Kwanakin daidaita kayan aikin gwaji, yanayin muhalli yayin gwaji, da kuma ko wani ɓangare na uku mai zaman kansa ya shaida gwaje-gwajen.

Kashi na Huɗu: Gwajin Karɓar Masana'anta—Abin da Masu Sayayya Ya Kamata Su Sani

Ga muhimman ayyuka, masu saye kan shaida gwaje-gwajen Karɓar Masana'antu (FAT). Wannan yana tabbatar da cewa na'urar canza wutar lantarki ta cika ƙa'idodi kafin a kawo ta.

Mafi kyawun hanyoyin sun haɗa da:

  • Yin bitar tsarin gwaji kafin fara ƙera
  • Tabbatar da cewa an haɗa na'urar transfoma gaba ɗaya don gwaji (tare da dukkan abubuwan da aka haɗa)
  • Tabbatar da cewa kayan aikin gwaji an daidaita su yadda ya kamata
  • Yin rikodin duk sakamakon tare da tambarin lokaci da kuma gano mai aiki

Wasu masana'antun yanzu suna ba da FAT na kama-da-wane, suna ba da damar yin shaida daga nesa - madadin da zai iya rage farashi lokacin da tafiya ba zai yiwu ba.

Kammalawa

Gwajin na'urorin canza wutar lantarki da takaddun shaida ba ƙa'idodi ba ne na tsarin mulki—su ne muhimman hanyoyin tabbatar da inganci. Gwaje-gwaje na yau da kullun suna kama lahani na masana'antu. Gwaje-gwajen nau'i suna tabbatar da injiniyanci. Takaddun shaida suna ba da damar shiga kasuwa da kuma tabbatar da wani ɓangare na uku.

Ga ƙwararrun masu sayayya, ɗaukar lokaci don fahimtar rahotannin gwaji da buƙatun takaddun shaida yana ba da riba a cikin amincin kadarori da rage haɗarin dokoki. Na'urar canza wutar lantarki da ta zo tare da cikakkun takaddun gwaji masu inganci tana da yuwuwar samar da sabis na shekaru da yawa ba tare da matsala ba.