Gabatarwa

A mafi yawan rayuwarsu ta aiki, na'urorin transfoma suna aiki cikin shiru. Matsaloli suna tasowa a cikin gida - rufin yana lalacewa, haɗin yana sassautawa, wuraren zafi suna tasowa - ba tare da wani gargaɗi ba. Lokacin da kariya ta al'ada ta fara aiki, galibi lalacewa ta riga ta ƙare.

Tsarin sa ido ta yanar gizo yana canza wannan. Suna ba wa na'urorin canza wutar lantarki murya, suna ba da damar ganin yanayin cikin gida akai-akai da kuma ba wa ƙungiyoyin gyara damar yin aiki kafin a sami matsala. Ga ƙwararrun masu siye, fahimtar abin da waɗannan tsarin za su iya yi yana da mahimmanci don ƙayyade kayan aiki da kimanta ƙwarewar masu samar da kayayyaki.

Kashi na Ɗaya: Me Ya Sa Ake Ci Gaba da Kulawa?

Kulawa ta gargajiya ta dogara ne akan duba lokaci-lokaci - samfuran mai da ake ɗauka duk wata uku, gwajin zafi a kowace shekara, gwajin wutar lantarki duk bayan 'yan shekaru. Tsakanin waɗannan hotunan, manyan canje-canje na iya ɓacewa ba tare da an gano su ba.

Sa ido ta yanar gizo yana rufe wannan gibin. Na'urori masu auna sigina suna bin diddigin muhimman sigogi 24/7, suna gano yanayin da ba a saba gani ba yayin da suke tasowa. Bincike ya nuna cewa gyaran da aka yi ta hanyar ci gaba da sa ido zai iya rage katsewar da ba a shirya ba da sama da kashi 40 cikin 100 yayin da yake rage farashin gyara da sama da kashi 30 cikin 100.

Shari'ar tattalin arziki abin birgewa ne. Tsarin koyon na'ura da aka yi amfani da shi Na'urar Canza Rarrabawas ya cimma daidaito kashi 94.7 cikin ɗari wajen hasashen gazawa kwanaki 30 zuwa 90 kafin a fara aiki, wanda hakan ya samar da riba kashi 260 cikin ɗari kan jarin da aka zuba.

Kashi na Biyu: Fasahar da ta fi muhimmanci

Binciken Iskar Gas da Aka Narke (DGA).DGA ta kasance ginshiƙin sa ido kan na'urorin canza wutar lantarki. Idan kurakurai na ciki suka faru—zafi fiye da kima, fitar da wani ɓangare, ko kuma rugujewa—ƙarfin da aka saki yana lalata ƙwayoyin mai, yana samar da iskar gas mai halaye. Hydrogen yana nuna corona; ethylene yana nuna lahani na zafi; acetylene yana nuna ƙarfin wutar lantarki mai yawa.

DGA ta yanar gizo tana sa ido kan fitar da mai da kuma nazarin mai akai-akai, tana gano canje-canje a cikin yawan iskar gas a cikin mintuna maimakon watanni. Tsarin da aka yi amfani da laser na zamani yana samun sauƙin amsawa ƙasa da 0.1 ppm ga iskar gas mai mahimmanci kamar acetylene, wanda ke ba da damar gargaɗin farko game da lahani da ke tasowa.

Kulawa da Saki na Wani Lokaci (PD).Fitar da wani ɓangare ƙananan tartsatsin lantarki ne a cikin lahani na rufi. Duk da cewa ba za su iya haifar da matsala nan take ba, suna lalata rufin akan lokaci. Sa ido kan PD yana gano waɗannan fitar ta hanyoyi da yawa: Na'urori masu auna sigina na UHF suna kama fitar da hayaki na lantarki; na'urori masu auna sigina na ultrasonic suna gano girgizar sauti; na'urori masu auna sigina na HFCT suna auna bugun wutar lantarki.

Haɗakar na'urori masu auna firikwensin da yawa yana inganta daidaito sosai. Haɗakar gano na'urorin lantarki da sauti na iya gano tushen PD a cikin santimita 10-20, wanda ke ba da damar kulawa da aka yi niyya.

Kula da Zafin Jiki.Ga kowace ƙaruwar zafin jiki na 8-10°C sama da zafin da aka ƙididdige, tsawon rayuwar rufin yana rabi. Yanayin zafi mai zafi - ba kawai mai mai ba - yana ƙayyade yawan tsufa. Na'urori masu auna firam-optic da aka saka a cikin windings suna ba da ma'aunin zafi kai tsaye, ba tare da tsangwama ga wutar lantarki ba.

Kashi na Uku: Daga Bayanai zuwa Shawara

Bayanan firikwensin da ba a tantance ba suna da amfani ne kawai idan aka fassara su. Tsarin sa ido na zamani yana haɗa sigogi da yawa, yana amfani da nazarin bayanai don samar da fahimta mai amfani.

Fihirisar Lafiya.Tsarin Static Asset Health Index (SAHI) ya haɗa sakamakon DGA, gwaje-gwajen lantarki, tarihin kulawa, da bayanan aiki zuwa maki ɗaya na lafiya. Wannan yana ba da damar fifita rundunar jiragen ruwa da kuma shiga tsakani bisa ga yanayi.

Wani lamari na zahiri ya nuna darajar: na'urar transformer ta nuna ƙaruwar hydrogen da methane a cikin watanni uku. Binciken SAHI, wanda ya haɗa da sakamakon gwajin ƙarfin lantarki da ma'aunin danshi, ya nuna haɗarin fitar da wani ɓangare na fitarwa da kuma shawarar cire shi daga aiki. Binciken cikin gida ya tabbatar da ganewar asali - gurɓataccen mai yana haifar da aikin PD. Sauya mai ya warware matsalar, yana hana abin da zai iya zama babban gazawa.

Haɗakar Koyon Inji.Tsarin zamani yana amfani da koyon na'ura ga bayanan tarihi, yana koyon tsarin halayen kowace na'ura mai canza wutar lantarki. Lokacin da aka sami karkacewa, algorithms suna nuna rashin daidaituwa makonni kafin iyakokin gargajiya.

Kashi na Huɗu: Zaɓar Tsarin Kulawa

Ga ƙwararrun masu siye, akwai abubuwa da dama da ya kamata a yi la'akari da su.

Rufin Sigogi.Ba duk masu saka idanu iri ɗaya ba ne. Tsarin asali yana bin diddigin DGA kawai; cikakkun dandamali suna haɗa DGA, PD, zafin jiki, danshi, da bayanan kaya. Yi la'akari da waɗanne sigogi ne suka fi muhimmanci ga aikace-aikacenka.

Ingancin Na'urar Firikwensin.Manyan alamun aiki sun haɗa da kewayon ganowa, daidaiton ma'auni (yawanci ± kashi 5), da kuma maimaituwa (bambancin

Yarjejeniyar Sadarwa.Ya kamata na'urorin saka idanu su haɗa kai da kayayyakin more rayuwa na SCADA ta hanyar Modbus, IEC 61850, ko wasu ka'idoji na yau da kullun. Tabbatar da dacewa kafin siyan.

Ƙarfin Nazarin.Nazarin kan na'ura wanda ke samar da faɗakarwar da aka fi so ya fi na tattara bayanai marasa inganci. Nemi tsarin da ke ba da nazarin yanayi, faɗakarwar saurin canji, da kuma ma'aunin lafiya.

Kammalawa

Sa ido kan yanar gizo na Transformer ya girma daga wata fasaha ta musamman zuwa babbar kayan aikin sarrafa kadarori. DGA tana gano canje-canjen sinadarai, PD tana gano lahani na lantarki, na'urori masu auna zafin jiki suna bin diddigin damuwar zafi - tare, suna ba da cikakken gani game da lafiyar transformer.

Ga ƙungiyoyin da ke kula da muhimman kadarori, tambayar ba yanzu ba ce ko za a sa ido a kansu, amma ta yaya za a yi su sosai. Na'urar canza wutar lantarki da ke magana—ta hanyar na'urori masu auna firikwensin da nazarinta—tana ba wa ƙungiyoyin kulawa damar sauraro, fahimta, da kuma yin aiki kafin gazawa ta faru.