+86 18068001229 Na'urar Canzawa Mai Amorphous Alloy Da Na'urar Canzawa Karfe Ta Silicon
Shin ka san bambanci tsakanin Na'urar Canza Amorphous Alloys da kuma na'urorin canza wutar lantarki na silicon na yau da kullun? A matsayinka na mai ƙera na'urorin canza wutar lantarki mai shekaru 15+ na gwaninta, JZP ya bayyana bambance-bambancen da ke tsakanin waɗannan nau'ikan na'urorin canza wutar lantarki guda biyu. Ba wai kawai bambanci ne a cikin kayan aiki ba; yaƙi ne na fasaha tsakanin ingancin makamashi, farashi, da kuma yanayin da ake ciki a nan gaba.
Na'urar Canzawa ta Amorphous da Transformer ta Al'ada
Na'urar Canza Karfe ta Silicon ta Talakawa
Na'urorin canza wutar lantarki na yau da kullun suna da tsakiya da aka yi da zanen ƙarfe na silicon mai launin sanyi, wanda aka tsara su a cikin tsari mai kyau da tsari na yau da kullun.
Wannan tsari mai tsari yana haifar da ƙarancin juriyar maganadisu idan aka haɗa su da maganadisu a kan hanyar birgima, wanda ke haifar da kyakkyawan aiki. Duk da haka, har yanzu suna da lu'ulu'u, kuma maganadisu yana cinye makamashi, yana haifar da "asarar hysteresis." Bugu da ƙari, zanen ƙarfe na silicon yana da wani kauri, kuma filayen maganadisu masu canzawa suna haifar da "ƙarfin eddy" a cikinsu, wanda ke haifar da "asarar eddy current," wanda aka fi sani da "asarar ƙarfe."
Na'urar Canza Amorphous Alloy
An yi tsakiyar na'urar canza wutar lantarki mai siffar amorphous da ribbon mara siffa, wanda kuma aka sani da "gilashin ƙarfe." Tsarin atomic ɗinsa yana da rudani da rashin tsari. Wannan tsari yana samuwa ne ta hanyar sanyaya narkewar zafin jiki mai tsanani da sauri a saurin miliyoyin digiri a kowace daƙiƙa, wani tsari na musamman. Wannan matsalar atomic mai tsayi yana rage asarar hysteresis sosai; kauri mai siririn gaske da juriya mai yawa suna ƙara rage asarar wutar lantarki mai ƙarfi.
Kwatanta Aiki
| Girman Kwatanta | Na'urar Canza Amorphous Alloy
| Na'urar Canza Karfe ta Silicon ta Talakawa
| Bincike da Fassara
|
| Asarar Babban
| Ƙasa Matuƙa
| Babban
| Asara mara nauyi, a matsakaici, ta fi ƙasa da kashi 60%-80% idan aka kwatanta da na'urorin canza ƙarfe na silicon S13/S14.
|
| Babu-kaya Yanzu
| Ƙarami
| Babba
| Ana iya rage wutar lantarki mara nauyi da kusan kashi 40%-80%, wanda ke nufin ƙarancin tasirin wutar lantarki akan grid da asarar layukan da ba su da yawa.
|
| Matakin Inganta Makamashi
| Babban Maɗaukaki
| Babban
| Na'urorin canza wutar lantarki marasa tsari suna cika ƙa'idar ingancin makamashi ta ƙasa ta Aji I cikin sauƙi, wanda ke wakiltar mafi girman ingancin makamashi idan aka kwatanta da na'urorin canza wutar lantarki na ƙarfe na silicon (yawanci Aji II ko Aji III).
|
| Kudin Masana'antu
| Babban
| Ƙananan
| Layin ƙarfe mai siffar amorphous yana da tsada, mai tauri, kuma yana da rauni, kuma hanyoyin yankewa da kuma cirewa suna da sarkakiya, wanda ke haifar da farashin masana'antu ya fi na ƙarfe silicon mai irin wannan ƙarfin da kashi 20%-35%. Wannan shine babban rashin amfaninsa.
|
| Ƙarfin Inji
| Ƙasa
| Babban | Layin ƙarfe mai siffar amorphous yana da tauri da karyewa, ba shi da juriya ga girgiza da girgiza. Ya kamata a yi taka tsantsan musamman yayin jigilar kaya, shigarwa, da girgizar da ba ta da ƙarfi. Takardar ƙarfe ta silicon ta fi ƙarfi kuma tana da juriyar tasiri mafi kyau.
|
| Yawan kwararar maganadisu mai aiki
| Ƙasa (1.3-1.5T)
| Babban (1.6-1.8T)
| Yawan kwararar maganadisu mai cikewa na amorphous alloys yana da ƙasa, wanda ke nufin cewa ana buƙatar babban yanki na giciye na tsakiya a irin wannan ƙarfin, wanda zai iya haifar da ɗan ƙaruwa a cikin girma da nauyin na'urar canza wutar lantarki.
|
| Hayaniyar Aiki
| Ɗan tsayi kaɗan
| Ƙasa
| Tasirin magnetostrictive (ƙaramin canji a girman abu lokacin da aka haɗa shi da maganadisu) na amorphous alloys ya fi bayyana fiye da na silicon steel sheeps, wanda ke haifar da ɗan ƙara hum (kimanin 2-5 dB sama) yayin aiki. Ana iya buƙatar kulawa ta musamman a wurare masu saurin jin hayaniya.
|
| Ayyukan Muhalli
| Madalla sosai
| Mai kyau | Rage asarar da ba ta da kaya sosai yana nufin babban tanadin makamashi a tsawon zagayowar rayuwa (shekaru 20-30), daidai da rage fitar da hayakin carbon da tan da dama ko ma tan goma. |
Na'urorin canza wutar lantarki na silicon na yau da kullun: Ƙananan jarin farko, amma tsadar wutar lantarki mai yawa. Asarar wutar lantarki da suke yi ba tare da kaya ba tana faruwa awanni 24 a rana, tana cinye wutar lantarki mai ci gaba matuƙar na'urar canza wutar lantarki tana da haɗin grid.
Na'urorin canza wutar lantarki marasa tsari: Babban jarin farko, amma ƙarancin kuɗin wutar lantarki mai aiki. Tanadin makamashin su na iya zama ba shi da yawa a rana ɗaya, amma a tsawon rayuwarsu (shekaru 20-30), tanadin zai iya zama mai ban mamaki.
Ga manyan kamfanoni masu yawan jama'a Na'urar Canza Rarrabawas da ƙananan abubuwan da ke haifar da nauyi (kamar kamfanonin grid na wutar lantarki, cibiyoyin bayanai, da manyan cibiyoyin kasuwanci), fa'idodin tattalin arziki na amorphous transformers suna da matuƙar kyau.