+86 18068001229 Inganta Rarraba Wutar Lantarki a Masana'antu Dole ne a Karanta: Yadda Na'urorin Canza Wutar Lantarki Masu Inganci na JZP Ke Taimakawa Kamfanoni Rage Kudaden Makamashi da kashi 30%.
Gabatarwa: Muhimmancin Ingantaccen Makamashi
Karin farashin makamashi da tsauraran ƙa'idojin carbon suna tilasta wa masana'antu sake tunani game da tsarin wutar lantarkinsu. Na'urorin canza wutar lantarki na gargajiya, waɗanda ke fama da asara mai yawa, ba su da amfani. Na'urorin canza wutar lantarki masu ƙarfi na JZP masu adana makamashi masu inganci sun bayyana a matsayin mafita mai kawo sauyi, suna haɗa injiniyanci na zamani tare da tanadi mai ma'ana. Ga yadda suke cimma rage farashin makamashi har zuwa kashi 30% yayin da suke aiki don kare muhalli a nan gaba.
- Ingantaccen Tsarin Fasaha na Core
- Kayan Aiki na Magnetic Core na Ci gaba
Na'urorin canza wutar lantarki na JZP suna amfani da ƙananan ƙarfe masu kama da ƙarfe da kayan nano-crystalline, waɗanda ke rage asarar hysteresis da eddy current da kashi 40-50% idan aka kwatanta da ƙananan ƙarfe na silicon na gargajiya. Wannan yana rage asarar da ba ta da kaya (asarar asali) zuwa ƙasa da kashi 0.2% na ƙarfin da aka ƙididdige, wanda ya yi daidai da ƙa'idodin ingancin makamashi na GB20052-2020 na China.
- Tsarin Sanyaya Mai Hankali
Gudanar da yanayin zafi mai ƙarfi yana daidaita ƙarfin sanyaya bisa ga yanayin kaya:
Fanka masu saurin canzawa: Rage kuzarin sanyaya da kashi 30% a lokacin ƙarancin kaya.
Watsar da zafi da aka nutsar da mai: Yana ƙara ingancin canja wurin zafi da kashi 20%, yana rage asarar da ke da alaƙa da zafin jiki.
- Tsarin Winding Mafi Kyau
Na'urorin jan ƙarfe masu ƙarancin juriya: Rage asarar kaya (asarar jan ƙarfe) ta hanyar rage ƙarfin juriya.
Daidaita juriyar gajere: Yana iyakance canjin wutar lantarki da asarar sakandare yayin rikicewar grid.
- Rage Kuɗi da Manufofi ke Haifarwa da Tasirin Kuɗi
- Tallafin Gwamnati
China: Har zuwa ¥200,000 tallafin maye gurbin na'urorin canza wutar lantarki na S7/S9 da maki S13/S15.
EU: Harajin da ake biya don na'urorin canza wutar lantarki da suka cika matakan inganci na IEC 60076-11.
- Binciken Ribar Zuba Jari
- Dabaru don Aiwatarwa Mafi Girma
Bayanin Load: Yi amfani da mita masu wayo don gano tsarin amfani da kololuwa/babu kololuwa.
Girman Na'urar Canzawa: Daidaita ƙarfin da ake buƙata da ainihin buƙata (a guji manyan na'urori).
Sake gyarawa: Sauya tsoffin na'urori a matakai don rage lokacin aiki.
Kulawa Mai Hasashen: Haɗa na'urori masu auna IoT don sa ido kan yanayin zafi da lafiyar rufin gida a ainihin lokaci.
- Tabbatar da Makomaki tare da Haɗin Kai Mai Sabuntawa
An tsara na'urorin canza wutar lantarki na JZP don sassaucin grid:
Gudanar da wutar lantarki ta hanyoyi biyu: Yana haɗa makamashin rana/iska cikin layukan wutar lantarki na masana'antu ba tare da wata matsala ba.
Rage ƙarfin jituwa: Matatun da aka gina a ciki suna rage karkacewa daga nauyin da ba na layi ba (misali, VFDs).
Kammalawa: Ingantaccen Makamashi a Matsayin Kadari Mai Mahimmanci
Na'urorin Canza Inganci Masu Inganci na JZP ba wai kawai na'urori ne masu rage farashi ba—su ne kadarori na dabaru da suka dace da manufofin dorewa na duniya. Ta hanyar rage asara, rage kuɗaɗen shiga, da kuma tallafawa haɗin kai mai sabuntawa, JZP tana ƙarfafa masana'antu su bunƙasa a nan gaba mai amfani da makamashi.