A shekarar 2024, mun kai na'urar transformer mai karfin MVA 12 zuwa Philippines. Wannan na'urar transformer tana da karfin KVA 12,000 kuma tana aiki a matsayin na'urar transformer mai saurin sauka, tana canza babban ƙarfin lantarki na 66 KV zuwa babban ƙarfin lantarki na 33 KV. Muna amfani da jan ƙarfe don kayan naɗewa saboda ingantaccen ƙarfin lantarki, ingancin zafi, da juriya ga tsatsa.
An ƙera shi da fasahar zamani da kayan aiki masu inganci, na'urar canza wutar lantarki ta MVA mai ƙarfin 12 tana ba da aminci da dorewa mai kyau.
A JZP, muna ba da garantin cewa kowace na'urar transfoma da muke bayarwa za ta fuskanci gwajin karɓuwa mai kyau. Muna alfahari da cewa mun riƙe tarihin rashin laifi na tsawon sama da shekaru goma. An nutsar da mu a cikin mai. Masu Canza Wutar Lantarki an ƙera su don cika ƙa'idodin IEC, ANSI, da sauran manyan ƙayyadaddun bayanai na duniya.
 
Faɗin Samarwa
Samfuri: Na'urar Canza Wutar Lantarki Mai Nutsewa a Cikin Mai
Ƙarfin da aka ƙima: Har zuwa 500 MVA
Babban ƙarfin lantarki: Har zuwa 345 KV
 
Bayanin Fasaha
Takaddun bayanai na na'urar canza wutar lantarki ta MVA 12 da takardar bayanai

Samfuri SFZ11-12 MVA-66/33KV
Nau'i Na'urar canza wutar lantarki mai nutsewa 0il
Daidaitacce IEC60076
Ƙarfin da aka ƙima 12000 KVA
Mita 60HZ
Mataki 3
Nau'in Sanyaya BA A KAN MAGANCE MATSALOLI BA
Babban ƙarfin lantarki 66 KV
Wutar Lantarki ta Biyu 33 KV
Kayan Nadawa Tagulla
Ƙungiyar Vector Ynd1
Impedance 10%
Mai Canza Taɓawa OLTC
Nisan Taɓawa ±8*1.25%
Kayan haɗi Daidaitacce
Bayani Ba a Samu Ba

Hanyar sanyaya ta Na'urar Canzawa Mai Nitsewa Yawanci yana ƙunshe da amfani da man transformer a matsayin babban hanyar sanyaya. Wannan man yana da manyan manufofi guda biyu: yana aiki a matsayin mai hana wutar lantarki kuma yana taimakawa wajen wargaza zafi da ake samu a cikin na'urar transformer. Ga wasu hanyoyin sanyaya da aka saba amfani da su a cikin na'urorin transformer da aka nutsar da mai:
1. Man Fetur na Halitta Iskar Halitta (ONAN)
● Bayani:
A wannan hanyar, ana amfani da na'urar haɗa mai ta halitta don yaɗa mai a cikin tankin na'urar canza wutar lantarki.
o Zafin da na'urorin transformer ke samarwa yana shanyewa ta hanyar mai, wanda daga nan zai tashi ya kuma tura zafi zuwa bangon tanki.
o Zafin yana wargazawa zuwa cikin iskar da ke kewaye ta hanyar fitar da iska ta halitta.

● Aikace-aikace:
o Ya dace da ƙananan na'urorin canza wutar lantarki inda zafin da ake samu bai wuce kima ba.

● Bayani:
o Wannan hanyar tana kama da ONAN, amma ta haɗa da zagayawar iska da ake tilastawa.
Ana amfani da fanka don hura iska a saman radiator na na'urar transformer, wanda ke inganta tsarin sanyaya.

● Aikace-aikace:
o Ana amfani da shi a cikin matsakaicin girman transfoma inda ake buƙatar ƙarin sanyaya fiye da iskar da ke shiga ta halitta.

● Bayani:
A cikin OFAF, ana yaɗa mai da iska ta amfani da famfo da fanka, bi da bi.
o Famfon mai suna zagaya mai ta cikin na'urar transformer da radiators, yayin da fanka ke tilasta iska ta cikin radiators.

● Aikace-aikace:
o Ya dace da manyan na'urorin canza wutar lantarki inda na'urar sanyaya iska ta halitta ba ta isa ta sanyaya ba.

● Bayani:
o Wannan hanyar tana amfani da ruwa a matsayin ƙarin wurin sanyaya.
Ana yaɗa mai ta hanyar na'urorin musayar zafi inda ruwa ke sanyaya mai.
o Sannan a sanyaya ruwan ta hanyar wani tsari daban.

● Aikace-aikace:
Ana amfani da shi a manyan na'urori masu canza wutar lantarki ko shigarwa inda sarari don sanyaya iska ke da iyaka kuma ana buƙatar ingantaccen aiki.

● Bayani:
o Kamar OFAF, amma tare da kwararar mai da aka tsara.
Ana tura man ta wasu hanyoyi ko bututun iska domin inganta sanyaya a wasu wurare masu zafi a cikin na'urar canza wutar lantarki.

● Aikace-aikace:
o Ana amfani da shi a cikin na'urorin canza wutar lantarki inda ake buƙatar sanyaya da aka yi niyya don sarrafa rarrabawar zafi mara daidaito.

● Bayani:
o Wannan wata hanya ce ta sanyaya iska mai zurfi inda ake tura mai ya ratsa ta wasu hanyoyi a cikin na'urar canza wutar lantarki, don tabbatar da sanyaya da aka yi niyya.
o Daga nan sai a mayar da zafi zuwa ruwa ta hanyar na'urorin musanya zafi, tare da tilasta zagayawa don kawar da zafi yadda ya kamata.

● Aikace-aikace:
o Ya dace da manyan na'urori masu aiki da wutar lantarki ko kuma masu amfani da wutar lantarki a masana'antu ko aikace-aikacen amfani inda daidaitaccen tsarin kula da zafin jiki yake da mahimmanci.

2. Man Fetur na Halitta Mai Ƙarfin Iska (ONAF)
3. Sojan Sama da Aka Yi Amfani da Man Fetur (OFAF)
4. Ruwan da aka tilasta wa mai (OFWF)
5. Rundunar Sojan Sama Mai Jagoranci (ODAF)