+86 18068001229 Kwatanta Fasaha: Na'urar Canzawa ta Keɓewa da Na'urar Canzawa ta Al'ada
- Manufofin Aiki na Musamman
Transfoma na yau da kullun
An tsara shi musamman don juyawar ƙarfin lantarki (mataki-mataki-sama/ƙasa), tare da daidaiton juyi tsakanin naɗewar farko/na sakandare. Babban manufarsu ita ce canza ƙarfin lantarki na AC don biyan buƙatun kaya.
Mayar da hankali kan warewar galvanic maimakon gyaran ƙarfin lantarki. Duk da cewa wasu samfura suna riƙe da rabon juyawa 1:1, muhimmiyar rawar da suke takawa ita ce karya hanyoyin lantarki kai tsaye tsakanin tushe da kaya don tabbatar da aminci.
- Falsafar Zane
Transfoma na yau da kullun
An gina shi da haɗin maganadisu wanda ke ba da damar canza ƙarfin lantarki. Masu canza wutar lantarki na atomatik (wani nau'in ƙasa) suna raba na'urorin juyawa don ƙaramin ƙira amma ba su da ƙarfin keɓewa.
Masu Canza Canjin Kullewa
Keɓewa mai juyewa biyu tare da kariyar lantarki. Sabbin samfura sun haɗa da kejin Faraday don rage hayaniya da abubuwan da ke faruwa a yanayi na yau da kullun.
- Bayanan Tsaro
| Sigogi | Na'urar Transfoma ta Yau da Kullum | Na'urar Canzawa ta Warewa |
| Ƙarfin Dielectric | 1,000V (na yau da kullun) | ≥1,500V (IEC 61558-1 ya dace) |
| Ɓoyewar Wutar Lantarki | Har zuwa 3.5mA |
|
| Tsarin Gina Ƙasa | Tsaka-tsaki a ƙasa | Ƙasa mai iyo ko kuma ƙasa mai zaɓe |
- Yanayin Aikace-aikace
Transfoma na yau da kullun
Tsarin sarrafa sarrafa kai na masana'antu
Manufa ta gabaɗaya Rarraba Wutar Lantarki (misali, canza 380V → 220V)
Aikace-aikace masu sauƙin amfani ba tare da tsauraran buƙatun aminci ba
Masu Canza Canjin Kullewa
Kayan aikin daukar hoton likita (na'urorin daukar hoton MRI/CT)
Kayan aikin dakin gwaje-gwaje da tsarin sauti/bidiyo
Hanyoyin makamashi masu sabuntawa (masu canza hasken rana)
- Aiwatar da Fasaha
Ayyukan Wayoyi
Na yau da kullun: Haɗin kai tsaye-tsaka-tsaki-tsaki
Warewa: Layukan PE/N da aka keɓe tare da sa ido kan rufin
Aikin EMI
Na yau da kullun: Mai sauƙin kamuwa da hayaniya (harmonics 50/60Hz)
Warewa: > 60dB rabon kin amincewa da yanayin gama gari (CMRR)
- Ka'idojin Biyayya
Na yau da kullun: IEC 60726-2 (aikace-aikacen masana'antu)
Keɓewa: IEC 61558-1/2 (tsarin da ke da mahimmanci ga aminci), UL 1950 (na'urorin likitanci)
Wannan kwatancen da aka tsara ya nuna yadda na'urorin canza wutar lantarki ke samar da muhimman fa'idodin tsaro ta hanyar fasahar zamani ta rufewa da rage hayaniya, yayin da na'urorin canza wutar lantarki na yau da kullun ke ba da fifiko kan sauya wutar lantarki mai inganci da farashi. Zaɓin ya dogara ne da takamaiman buƙatun aminci na lantarki da yanayin aiki.