+86 18068001229 01
Na'urar Canzawa Mai Mataki Uku 2000kVA
Bayanin Samfurin
An tura na'urorin transformer masu ƙarfin 2000kVA, 34.5kV na JZP Transformer a cikin Tsarin Ajiyar Makamashin Baturi (BESS) a Kern County, California, inda suke samar da ingantaccen wutar lantarki don tallafawa kayan aiki daban-daban a cikin tashar ajiyar makamashi. An kammala su a watan Mayu na 2024 kuma an isar da su ga abokan cinikin Amurka, waɗannan na'urorin transformers suna da mahimmanci don tabbatar da aiki ba tare da katsewa ba da kuma ingantaccen sarrafa ajiyar makamashi.
01020304050607
| Yanayin zafi na yanayi | Mafi ƙarancin -15.0°C, Matsakaicin 41.0°C, matsakaicin matsakaicin awanni 24 33.0°C |
| Tsawo | |
| Yanayin girgizar ƙasa: | Nau'in Hadari: II, Ajin Rukunin D |
| SS = 1.28 g, S1 = 0.43 g, SMS = 1.54 g, SM1 = 1.09 g, SDS = 1.03 g, SD1 = 0.73 g |
| Aiki mara iyaka (mataki-zuwa-mataki) | 34.5kV |
| Matsakaicin aiki (mataki-zuwa-mataki) | 38kV |
| Tsarin juyawa | Delta |
| Matsayin Bushing | 600A |
| Rufin rufi | 200kV BIL |
| Rufin katako | 200kV BIL |
| Yawan Bushing | Shida (Madauwari Ciyarwa) |
| Tsayayya ga gajeren da'ira | 30kA |
| Cire haɗin | Canjin LBOR |
| Cire adadin makullin haɗin | Mataki na 3 (1) Ɗaya (3) |
| Aiki mara iyaka (mataki-zuwa-mataki) | 480V |
| Tsarin juyawa | Wye da aka yi da ƙasa |
| Rufin rufewa da bushing BIL | Motar 30KV |
| Tsayayya ga gajeren da'ira | 65 kA* |
| Ramin ramin LV mai faɗi | (8) Babu rami 2 |
| Matsayin yawan ƙarfin lantarki na yau da kullun | 110% |
| An kafa juriya bisa tushe | A'a |
| Bas ɗin ƙasa | Ee |
| Ƙarfin wutar lantarki na samar da wutar lantarki ta sarrafawa | 277V AC |
| Bayanin mai karya da'ira | An jera UL |
| Ya dace da shiga sabis | Ee |
| Girma (in) | W*D*H: 83.9*94.7*95.3 |
| Tanki & Kayan Haɗi | 4,630lbs |
| Man mai girma | 900Gal |
| Jimlar Nauyi | 21,600lbs |
Muhimman Abubuwa & Fa'idodi
Ingancin Rarraba Wutar Lantarki don Ajiyar Makamashi
An tsara na'urorin transformers masu ƙarfin 2000kVA don sauka daga matsakaicin ƙarfin lantarki (MV) zuwa ƙarancin ƙarfin lantarki (LV), wanda hakan ya sa suka dace da haɗakar allunan sauyawa a cikin tsarin adana makamashi. Wannan tsarin saukar da wutar lantarki yana da mahimmanci don tabbatar da sassauƙa da ingantaccen rarraba wutar lantarki zuwa kayan aiki na taimako, yana tallafawa ingancin kayayyakin more rayuwa na BESS gaba ɗaya.
Sanyaya Mai Dorewa & Mai Inganci Mai Inganci
Daidai da jajircewar JZP Transformer ga dorewa, masu canza wutar lantarki suna amfani da man da za a iya lalata shi a matsayin ruwan sanyaya iska. Wannan mafita mai kyau ga muhalli ba wai kawai tana ba da kyawawan halaye na kariya ba, har ma tana tallafawa ingantaccen makamashi.
Dorewa & Tsaro a Gina-A ciki
Rufe-rufe na NEMA 3R: Na'urorin transformer ɗinmu suna cikin rufe-rufe na lantarki na NEMA 3R waɗanda ba sa yin ruwan sama, ba sa yin ƙanƙara, kuma ba sa yin dusar ƙanƙara, tare da wuraren magudanar ruwa da aka gina a ciki. Waɗannan rufe-rufe suna ba da kariya mai ƙarfi daga yanayi, suna kare sassan lantarki na ciki da kuma tabbatar da dorewar dogon lokaci ko da a cikin mawuyacin yanayi.
Sifofin Hana Canzawa da Tsaro: An tsara su ne da la'akari da tsaro, na'urorin canza wutar lantarki suna da hanyoyin kullewa da kullewa daban-daban don hana shiga ba tare da izini ba da kuma yin kutse, rage haɗarin sata da kuma tabbatar da aiki lafiya a kowane lokaci.
Tsarin da Ya Dace da Mai Amfani don Tsaro da Inganci
Gefen na'urar transformer mai ƙarancin ƙarfin lantarki yana da ƙira ta musamman da aka ɗora a gefe tare da makogwaro don sauƙin haɗawa da allon makulli. Ana sanya ma'aunin da aka ɗora a waje, bawuloli na samfuri, da tsarin magudanar ruwa a cikin kabad mai kullewa tare da makullin maƙulli mai maki biyar. Wannan ƙira ta musamman tana bawa masu aiki damar duba matakan mai lafiya, gwada ma'aunin, da kuma yin ayyukan gyara ba tare da fallasa kansu ga bushings masu ƙarfin lantarki (HV) ko ƙananan ƙarfin lantarki (LV) ba, wanda hakan ke ƙara inganta aminci da ingancin aiki sosai.

Ma'aunin transformer na waje da aka ɗora a kan kushin
Ci gaba da Kulawa & Faɗakarwa daga Nesa
Domin tabbatar da ci gaba da aiki mai kyau, na'urar canza wutar lantarki tana da alamun matakin mai da zafin jiki waɗanda ke da wuraren tuntuɓar juna biyu don sa ido daga nesa. Waɗannan alamun suna ba da bayanai na ainihin lokaci ga masu aiki, suna aika siginar faɗakarwa lokacin da matakin mai ya yi yawa ko ƙasa da haka. Bugu da ƙari, idan zafin ruwan sanyaya ya wuce 85°C, tsarin zai haifar da ƙararrawa. Idan zafin ya tashi sama da 105°C, na'urar canza wutar lantarki za ta cire haɗin wutar lantarki ta atomatik daga grid don hana zafi fiye da kima da yuwuwar lalacewa, ta tabbatar da aminci da amincin tsarin.

Inganci & Biyayya
Ana ƙera na'urorin canza wutar lantarki na JZP bisa ƙa'idodi masu tsauri na masana'antu, waɗanda suka haɗa da UL, ANSI, IEEE, da NEMA, suna tabbatar da aiki mai kyau, aminci, da aminci. Alƙawarinmu ga inganci da kirkire-kirkire yana tabbatar da cewa an gina kowace na'urar canza wutar lantarki bisa ga mafi girman ƙayyadaddun bayanai, tana ba da sabis mai inganci a tsawon rayuwar kayan aiki.

Yi tambaya yanzu!
Don tambayoyi game da samfuranmu ko mai lissafin farashi, da fatan za a bar mana imel ɗin ku kuma za mu tuntube ku cikin awanni 24.