Na'urar Canzawa Mai Mataki Uku 2500kVA

Matsayin Wutar Lantarki na Farko: 34.5-19.92/13.8-7.957/13.2-7.62/12.47-7.2 ko wasu
Matsayin Wutar Lantarki na Biyu: 208GrdY/120;416GrdY/240,480GrdY/277,/600GrdY/347,220y/127,480V,415v,600v ko wasu
JERIN TAP NA HV: ±2 × 2.5% ko wasu
NA'URAR HAƊAWA: Dyn11/YNyn0 ko wasu
NA'URI: Ciyar da madauki/Ciyar da radial
YAU: 30/150 kV
Ma'auni: IEEE, CSA, DOE
Aikace-aikace: BESS, Haƙar ma'adinai na Crypto, Masana'antu, Iska da makamashin rana, caji na EV
 Ƙimar Ƙarfi: 2500 kVA, 2550 kVA, 2.5 MVA
Takaddun shaida: UL, CUL, CSA, SGS

    Bayanin Samfurin

    JZP Transformer ƙwararriyar masana'antar na'urorin canza wutar lantarki ce wacce ke da jerin UL da takaddun shaida na matakan ƙarfin lantarki har zuwa 44kV, tana ba da cikakken kewayon na'urorin canza wutar lantarki da aka ɗora a kan UL. Kowace shekara, muna fitar da dubban waɗannan na'urorin canza wutar lantarki zuwa Amurka da Kanada. Ƙwarewa a cikin IEEE/ANSI, CSA, DOE, NEMA, da sauran ƙa'idodi, ƙungiyarmu tana tabbatar da bin ƙa'idodi daban-daban na ƙa'idoji. Baya ga takardar shaidar UL, muna kuma riƙe takaddun shaida na CSA, MF, CESI, da rahotannin gwaji na SGS na ɓangare na uku. Tare da ƙwarewar aiki mai yawa, mun fahimci cewa kowane aiki yana da buƙatu na musamman. Shi ya sa muke ba da na'urorin canza wutar lantarki da za a iya gyarawa, suna ba da damar daidaitawa ga ƙarfin lantarki, iya aiki, hanyar haɗi, da ƙira ta musamman don dacewa da buƙatunku. Ana iya keɓance na'urar canza wutar lantarki mai nauyin 2500 kVA don dacewa da buƙatun aikinku. Tuntuɓi Daelim Transformer a yau don karɓar takardar sigogi, zane-zane, da ƙiyasin na'urar canza wutar lantarki mai nauyin 2500 kVA.
    takardar shaida01
    takardar shaida02
    takardar shaida03
    takardar shaida04
    takardar shaida05
    takardar shaida06
    takardar shaida07
    takardar shaida08
    takardar shaida09
    01020304050607

    Bayanin Na'urar Canzawa 2500 kVA (2.5 MVA)

    Mataki Mataki uku Std. ANSI/IEEE Std C57 & DOE 2016 Std
    Ƙimar ƙarfi 2000kVA (2.5MVA) Saita Matattu gaba/madauri ciyarwa
    Haɗawa Shigar da Kushin Mita 60Hz
    Ƙarfin Wutar Lantarki na HV 13200/6720V Mai canza famfo Matsayi 5
    Ƙarfin Lantarki na LV 600/347V Ƙarfin Ruwa 1600L
    WACE MOTOCE 95 kV Jimlar nauyi 7000kG
    Motar LV 30 kV Babu asarar kaya 2500W
    Ƙungiyar Vektor A Cikin0 Asara a kan kaya 15000W
    Hanyar sanyaya KNAN Impedance 5.75%
    Kayan Nadawa Aluminum Launin Fenti Kore na Munsell
    Ruwan Rufi Man kayan lambu mai lalacewa Ƙarfin @ 65℃ Tashi a Zafin Jiki 2500 kVA
    Tsarin asali Mataki uku ginshiƙi biyar Iskar Tilas (Fansoshi) Babu

    Siffofin na'urar canza wutar lantarki ta 2500 kVA
    Siffofin na'urar canza wutar lantarki ta 2500 kVA
    Na'urar transformer ta ZGSL-H-2500/13.2-0.6 tana da ƙarfin wutar lantarki na 2500 kVA (2.5 MVA). Na'urar transformer mai nauyin 2500 kVA tana da ƙarfin wutar lantarki na farko na 13.2/7.62 kV tare da haɗin Wye, babban ƙarfin wutar lantarki na H0, da kuma ƙarfin lantarki na biyu na 600Y/347V Wye tare da ƙarancin ƙarfin wutar lantarki na H0.

    Na'urar canza wutar lantarki ta ZGSL-H-2500/13.2-0.6 2500 kVA tana da amfani mai yawa, kuma ta dace da shigarwa a cikin gida da waje. Waɗannan na'urorin canza wutar lantarki suna da ruwan da zai iya lalata man kayan lambu kuma suna kiyaye hauhawar zafin jiki na 65°C. Suna zuwa da fis ELSP guda 3 da fis 3 na bay-o-net don kariya, tare da bushings guda 3 masu ƙarfin lantarki, masu ɗaure gwiwar hannu guda 3 (HV) da bushings guda huɗu masu ƙarancin wutar lantarki, kowannensu yana da ramuka 6. Matsayin shigarwa na ƙarshen wutar lantarki mai ƙarancin wutar lantarki an ƙarfafa shi da farantin Paddount. Bugu da ƙari, na'urar canza wutar lantarki mai nauyin 2500 kVA tana da maɓallin karyewa mai matsayi huɗu da na'urar canza wutar lantarki mai matsayi biyar a gefen babban wutar lantarki.

    ZGSL-H-2500/13.2-0.6
    Na'urar ZGSL-H-2500/13.2-0.6 na'urar transformer ce mai matakai uku da aka ɗora da 2500 kVA mai jerin UL. Na'urar transformer mai nauyin 2500 kVA tana bin ƙa'idar IEEE C57.12.34 kuma tana bin ƙa'idodin DOE. An gina ta da na'urorin lantarki na aluminum kuma an tsara ta azaman na'urar transformer mai nau'in madauki don tsarin da ba shi da gaba. Hanyar sanyaya da ake amfani da ita ita ce KNAN.

    ZGS-Z-2500(3050)/44/0.6
    Na'urar ZGS-Z-2500(3050)/44/0.6 wata na'ura ce ta musamman da aka ɗora a gaban pad wadda aka ƙera don biyan buƙatun abokan cinikin Kanada ta Daelim Transformer. Wannan na'urar transformer mai nauyin 2500 kVA ta cika ƙa'idodin CSA C227.4 da CAN/CSA 802.1. Tana da ƙarfin lantarki mai yawa na 44 kV a cikin tsarin Delta da ƙarancin ƙarfin lantarki na 600GrdY/347V.

    Na'urar transformer ɗin tana da man RAPO mai lalacewa a matsayin ruwan da ke hana iska shiga kuma an tsara ta ne don ƙara yawan zafin jiki na 55°C ko 75°C. Matsayin kVA ɗinta shine 2500 kVA (2.5 MVA) a ƙaruwar zafin jiki na 55°C da kuma 3050 kVA a ƙaruwar zafin jiki na 75°C.

    ZGS-Z-2500(3050)/44/0.6
    Abin da ya bambanta wannan na'urar canza wutar lantarki mai ƙarfin 2500 kVA shi ne ƙarancin ƙarfin lantarki da aka ƙera shi don fita daga gefe. Bugu da ƙari, ma'aunin wutar lantarki, mai canza famfo, farantin suna, bawul ɗin rage matsin lamba, da kuma bawul ɗin cikawa na sama duk an sanya su a wajen ɗakin gaba. Waɗannan ma'aunin suna da alaƙa kuma an haɗa su a cikin akwatin sarrafawa na waje na NEMA 4. Ana sanya ma'aunin matsin lamba na injin tsotsa a saman ɗakin gaba. Babban ƙarfin lantarki mai ƙarfi bushing ne mai ramuka huɗu, kuma gefen HV yana da ma'aunin walƙiya guda uku, kowannensu yana ba da murfin rufi don kare kebul na MV. Bugu da ƙari, ana sanya masu dumama hana dumama a cikin ɗakin gaba mai ƙarfin lantarki don ingantaccen aiki.
    2

    Na'urar Canzawa ta 2.5 MVA 3 PH
    ZGSL-Z-2500/44/4.16(2.4) wata na'urar transformer ce ta musamman mai hawa uku mai hawa radial pad mai hawa 2.5 MVA. Babban ƙarfin wutar lantarkinsa shine Delta V 44,000, yayin da ƙarfin wutar lantarki na biyu shine 4160Y/2400 V. An tsara na'urar transformer ɗin tare da rukunin haɗin wutar lantarki mai girma da ƙasa na DYn1, kuma yana bin ƙa'idar CSA C227.4. Yana da ingantaccen ingantaccen makamashi na 99.37%, daidai da ƙa'idar CAN/CSA-802.3. Ƙarfin wutar lantarki na na'urar transformer a 85°C shine 5.75%, kuma yana ba da matakai bakwai na daidaita ƙarfin lantarki don ɓangaren wutar lantarki mai girma. Tare da ƙarfin mai mai rufi na 2000L da nauyin kilogiram 7500, kayan aiki ne mai mahimmanci.
    2

    Na'urar Transfoma ta MVA 2.5
    Abin lura shi ne, yana da tsari inda aka sanya sassan wutar lantarki masu girma da marasa ƙarfi a gefen da aka ɗora, tare da ɓangaren wutar lantarki mai girma wanda ke ɗauke da ɗakin tashar iska mai kyau wanda ya miƙe har zuwa tushensa. Haɗa bawuloli na kayan aiki da kayan haɗi masu tsari a bangon tankin mai na waje yana haɓaka isa ga mai amfani da wutar lantarki kuma yana tabbatar da ƙarin sauƙi, yana misalta ƙirar na'urar canza wutar lantarki mai kyau.
    Na'urar Canzawa Mai Sanya Faifan 2550 kVA

    Na'urar Canzawa Mai Sanya Faifan 2550 kVA
    ZGSL-H-2550/34.5/0.415 yana wakiltar na'urar transformer mai ƙarfi mai matakai uku da aka ɗora a kan madauri, tana da ƙarfin iko mai ban mamaki na 2550 kVA. Tana da ƙarfin ƙarfin lantarki mai girma na 34.5 kV yayin da take samar da ƙarancin wutar lantarki na 415Grd/240V. Abin lura shi ne, an ƙera na'urorin juyawa masu ƙarfi (HV) da ƙananan wutar lantarki (LV) da kyau daga aluminum. Wannan na'urar transformer mai ƙimar inganci na 99.4% kuma ta yi daidai da daidaitaccen ma'aunin IEEE Std C57.12.34. Bugu da ƙari, haɗa shi da maɓallin karyewa mai matsayi huɗu yana ƙara aiki da matakan aminci sosai.
    Na'urar Transfoma 2550 kVA

    Na'urar Transfoma 2550 kVA
    Na'urar canza wutar lantarki mai ƙarfin 2550 kVA tana amfani da tsarin sanyaya ONAN/ONAF, saboda haka, tana da fanka. Lokacin da ake aiki da hanyar sanyaya wutar lantarki ta ONAN, na'urar canza wutar lantarki tana da ƙarfin wutar lantarki na 2550 kVA. Duk da haka, hanyar sanyaya wutar lantarki ta ONAF na iya ɗaukar ƙarfin wutar lantarki mafi girma na 3300 kVA. Abin lura shi ne, na'urar canza wutar lantarki tana da na'urar auna zafin mai tare da lambobin ƙararrawa kuma an haɗa ta da ƙaramin kabad mai sarrafa ƙarfe mai ƙarfin 304. Wannan tsari yana ba da damar sa ido daga nesa game da yanayin aikin na'urar canza wutar lantarki.

    Jerin ZGSL-H-2550/34.5/0.415 ya ƙunshi jimillar raka'a huɗu, waɗanda aka tsara musamman kuma aka ƙera don abokan cinikin Amurka, kuma an tsara su don cika ƙa'idodin aminci da inganci masu tsauri.

    ZGSL-H-2550/12.47/0.415
    Jerin na'urorin ZGSL-H-2550/12.47/0.415 ya ƙunshi tarin na'urorin transformers 2550 kVA da JZP Transformer ya samar ga abokan cinikin Amurka. Waɗannan na'urorin transformers ɗin nau'in na'urorin ne da aka ɗora a kan pad kuma suna da tsarin ciyar da madauki. Muhimman bayanai na waɗannan na'urorin transformers sun haɗa da maɓallin karyewa mai matsayi huɗu, na'urar canza famfo mai matsayi biyar, na'urorin aunawa masu fasalin da ba a taɓawa ba, na'urorin fuse guda uku na bay-o-net, da kuma na'urorin fuse guda biyu masu iyakance halin yanzu.
    12

    Na'urar Transfoma 12.47 kV 2550 kVA
    A gefen ƙarancin wutar lantarki, akwai maƙallin da ke kan layi don samar da tallafi ga tashar. Ruwan kariya da ake amfani da shi shine man ma'adinai na ASTM II, wanda ke da ƙarfin galan 440. An ƙera tankin don jure matsin lamba mafi kyau na tanki 10 PSI da matsin lamba mara kyau na PSI 8. Ana kiyaye matakin ruwan a inci 10.0 daga saman ramin hannu a 25℃, tare da canjin matakin inci 0.4 a kowace 10℃. An ƙera tankin don cike injin tsotsar PSI 7 kuma an ƙididdige shi don 2550 kVA lokacin da aka kunna shi a volts 11,847 tare da mai canza famfo a matsayin volts 124,700 don ƙarfin lantarki na biyu na 415Y/240. Waɗannan na'urorin canza wutar lantarki ba su da matakan PCB da za a iya ganowa (ƙasa da 2 ppm) a lokacin ƙera su, suna tabbatar da amincin muhalli da bin ƙa'idodi.
    13

    Na'urar Transfoma 13.2 kV 2550 kVA
    Na'urar canza wutar lantarki mai ƙarfin 2550 kVA wata na'urar canza wutar lantarki ce da aka ƙera musamman wadda ke ɗauke da jerin UL, tana tabbatar da bin ƙa'idodin aminci da inganci masu tsauri. Rukunin haɗin wannan na'urar canza wutar lantarki shine Dy1·Dd0, tana ba da hanyoyi guda biyu daban-daban na haɗawa don ƙarancin wutar lantarki:

    Don haɗin Wye na 4160V, tashoshin sun haɗa da X1B, X2B, X3B don haɗin lokaci, X1A, X2A, da X3A don haɗin tsaka tsaki. Don haɗin Delta na 2400V, tashoshin sune kamar haka: C1B zuwa X2A, X2B zuwa X3A, da X3B zuwa X1A.
    24

    Na'urar Transfoma 24.94 kV 2550 kVA
    An gina dukkan na'urorin transformers masu nauyin 2550 kVA a cikin wannan jerin don dacewa da ƙa'idar IEEE C57.12.34, suna ba da garantin inganci da aiki mai kyau. Suna da ƙirar makogwaro mai hawa gefe don haɗin ƙananan ƙarfin lantarki, wanda ke ba da damar haɗa kayan juyawa ba tare da matsala ba. Bugu da ƙari, maɓallin karyewa na waɗannan na'urorin transformers masu nauyin 2550 kVA an ƙera su da kyau a cikin ɗakin ƙaramin matsin lamba na ɗakin gaba, yana ba da matsayi huɗu don iya aiki iri ɗaya. Na'urar canza famfo tana ba da matsayi biyar, kuma an saita kayan daidaita matsin lamba a 24.94±2×2.5% don daidaitaccen iko. Impedance na waɗannan na'urorin transformers a 85°C shine 5.87%, yana tabbatar da aiki mai dorewa da inganci. Bugu da ƙari, an ƙididdige matakan rufin su na babban ƙarfin lantarki da ƙarancin ƙarfin lantarki (BILs) a 125kV da 30kV, bi da bi, don tabbatar da ingantaccen aikin rufin.

    Yi tambaya yanzu!

    Don tambayoyi game da samfuranmu ko mai lissafin farashi, da fatan za a bar mana imel ɗin ku kuma za mu tuntube ku cikin awanni 24.