Na'urar Canzawa Mai Mataki Ɗaya da Aka Sanya—15KVA

Matsayin Wutar Lantarki na Farko: 12470 Delta V
Matsayin Wutar Lantarki na Biyu: 120/240V
JERIN TAP NA HV: ±2*2.5%
NA'URAR HAƊAWA: Ii6
NA'URI: Transformer da aka ɗora a kan sanda
YAU: 95/30kV
Ma'auni: IEEE C57.12.20, ANSI C57.12
Aikace-aikace: Amfani & rarrabawa

    Bayanin Samfurin

    JZP Transformer ƙwararre ne wajen kera na'urorin canza wutar lantarki guda 15 kVA waɗanda aka ɗora a kan sanda ɗaya waɗanda suka bi ƙa'idodin ƙasashen duniya masu ƙarfi, gami da IEEE C57.12.00, IEEE C57.12.20, Bukatun Inganci na DOE-2016, CSA C2.1 & C2.2, da CSA C802.1. Saboda jajircewarmu ga ƙwarewa, muna isar da mafita da aka tsara don daidaita daidai da takamaiman buƙatun fasaha na ku.
    Ko da kuwa matakin ƙarfin lantarki ko yanayin aiki da kuke buƙata, ku amince da JZP Transformer don samar da mafita mafi kyau da ta dace da takamaiman buƙatunku. Gamsuwarku, tare da amincin transformers ɗinmu mara sassauƙa, ta kasance ginshiƙin sadaukarwarmu ga samar da inganci mai kyau.
    Domin tabbatar da cewa an samar da ingantaccen tsarin isar da kayayyaki cikin sauƙi kuma cikin farashi mai rahusa, mun shirya kuma mun tattara dukkan na'urorin transfoma domin su dace da kwantena guda ɗaya mai girman 40HQ, tare da daidaita jigilar kayayyaki da kuma rage kuɗaɗen jigilar kayayyaki gaba ɗaya.
    Ta hanyar zaɓar na'urorin canza wutar lantarki na JZP, abokin ciniki zai iya kasancewa da kwarin gwiwa game da shawarar da ya yanke na saka hannun jari a cikin kayan aikin lantarki mafi girma, yana mai alƙawarin yin aiki mara misaltuwa da tanadin makamashi. Wannan alƙawarin ga inganci da dorewa ya yi daidai da manufarmu ta ba da gudummawa ga yanayin makamashi mai kyau da kuma ɗaukar nauyi.
    Na'urar Canzawa Mai Sanya 15kVA 21.6kV Mai Sanya 21.6kV
    Gabatar da DL-15/21.6/0.24(0.12), wata na'urar transformer mai inganci mai tsawon 15 kVA mai hawa ɗaya wacce aka ƙera ta da kyau kuma aka yi alfahari da ita, wacce JZP Transformer ya ƙera ta da kyau. Wannan na'urar transformer ta cika ƙa'idodin IEEE Std C57.12.00 da IEEE Std C57.12.20, tana tabbatar da aiki da aminci mai kyau.
    Tare da babban ƙarfin lantarki na 21.6 kV da ƙarancin ƙarfin lantarki na 240V (120V), DL-15/21.6/0.24(0.12) yana canza wutar lantarki yadda ya kamata don biyan buƙatun aikace-aikace daban-daban. Faɗin tsarin ƙarfin lantarkinsa ya bambanta daga 21600V zuwa 22680V yana ba da tabbacin fitarwar wutar lantarki mai daidaito da kwanciyar hankali, yana ba da damar aiki mai inganci koda a ƙarƙashin nauyi mai canzawa.
    Domin samar da ingantaccen rufi da kariya, na'urar canza wutar lantarki tana da karfin BIL (Matsayin Rufewa na Asali) na 125 kV don babban ƙarfin lantarki da kuma 30 kV don ƙarancin ƙarfin lantarki, tana kare daga hauhawar wutar lantarki da kuma tabbatar da dorewar aiki na dogon lokaci.
    15kVA 21
    Na'urar Canzawa Mai Sanya 15kVA 14.4kV Mai Sanya 14kV
    Gabatar da JZP-15/14.4(24.94)/0.24(0.12), wata na'urar transformer mai karfin kVA guda daya da aka sanya a sandar JZP da alfahari ta tsara kuma ta kera ta da alfahari.
    Yana da babban ƙarfin lantarki na 14.4 kV da ƙarancin ƙarfin lantarki na 240V (120V), ƙimar ƙarfin kVA na 15 kVA. DL-15/14.4(24.94)/0.24(0.12) yana tabbatar da ingantaccen canjin ƙarfin lantarki mai inganci don biyan buƙatun wutar lantarki daban-daban. An ƙera na'urorin juyawa masu ƙarfi da ƙarancin ƙarfin lantarki daga aluminum mai ɗorewa, wanda ke tabbatar da ingantaccen aiki da tsawon rai.
    An ƙera na'urar transformer tare da ƙarin polarity, wanda ke tabbatar da daidaito mara matsala da haɓaka aiki a cikin tsarin rarraba wutar lantarki.
    Tare da kewayon daidaita ƙarfin lantarki na 13680V zuwa 15120V, wannan na'urar canza wutar lantarki tana ba da tabbacin fitowar wutar lantarki mai ɗorewa da daidaito, tana ba da ingantaccen aiki a ƙarƙashin yanayi daban-daban na kaya. Babban BIL ɗinta (Matsayin Rufewa na Asali) na 95 kV da 30 kV yana tabbatar da kariya mai ƙarfi daga hauhawar wutar lantarki, yana haɓaka aminci da amincin na'urar canza wutar lantarki.
    15kVA 14
    Na'urar Canzawa Mai Sanya 15kVA 14.4kV Mai Sanya 14kV
    Ruwan da ake amfani da shi wajen rufewa shine mai ma'adinai mai inganci, babu PCB, wanda ke haɓaka aiki mai aminci da aminci ga muhalli. Tsarin sanyaya yana amfani da hanyar ONAN (Oil Natural Air Natural), yana wargaza zafi yadda ya kamata kuma yana kiyaye ingancin na'urar transformer.
    Bugu da ƙari, na'urar transformer mai ƙarfin 15kVA 14.4 kV tana da bushings guda biyu masu ƙarfin lantarki da bushings masu ƙarancin wutar lantarki guda uku, waɗanda ke ba da zaɓuɓɓukan haɗi masu sassauƙa. Bushings masu ƙarancin wutar lantarki suna da alaƙa da sandunan jan ƙarfe da aka yi amfani da su wajen yin ƙasa, wanda ke tabbatar da ingantaccen tsaro yayin aiki.
    Don aikace-aikacen matakai uku, ana iya haɗa na'urori masu canza wutar lantarki guda uku masu ƙarfin 14.4 kV waɗanda aka ɗora a kan sanda ɗaya yadda ya kamata don samar da wutar lantarki a 24.94 kV, wanda zai biya buƙatun masana'antu da na'urori daban-daban.
    Rahoton Gwajin Transfoma Mai Sanya 10kVA Pole6
    Na'urar Canzawa Mai Sanya 15kVA 7.2kV a Dogon Lokaci
    Gabatar da DL-15/7.2(12.47)/0.24(0.12), ita ce na'urar canza wutar lantarki mai hawa ɗaya da JZPTansor ya ƙera kuma ya ƙera. Wannan na'urar canza wutar lantarki tana da ƙarfin 15 kVA, wanda hakan ya sa ta dace da aikace-aikace daban-daban. Tare da ƙimar ƙarfin lantarki na farko na 7.2 kV (12.47 kV) da ƙimar ƙarfin lantarki na biyu na 120V (240V), wannan na'urar canza wutar lantarki tana tabbatar da ingantaccen canjin wutar lantarki don biyan buƙatun wutar lantarki daban-daban.
    Domin haɗa hanyoyin sadarwa da aikace-aikace daban-daban, DL-15/7.2(12.47)/0.24(0.12) ya zo da na'urorin bushing guda biyu masu ƙarfin lantarki da kuma na'urorin bushing guda uku masu ƙarancin ƙarfin lantarki, waɗanda ke da ƙirar ƙasa mai ƙarancin ƙarfin lantarki don inganta aminci.
    Tare da kewayon daidaita ƙarfin lantarki mai ban mamaki wanda ya fara daga 6840V zuwa 7560V, wannan na'urar canza wutar lantarki tana ba da garantin ingantaccen iko mai ƙarfi, yana tabbatar da rarraba wutar lantarki mai ƙarfi a cikin nau'ikan kaya daban-daban. Bugu da ƙari, DL-15/7.2(12.47)/0.24(0.12) yana nuna sauƙin amfani, kamar yadda na'urorin canza wutar lantarki guda uku na wannan ƙira za a iya haɗa su cikin sauƙi don samar da na'urar canza wutar lantarki mai matakai uku 12.47 kV, tana biyan buƙatun aikace-aikacen masana'antu da na amfani iri-iri.
    Rahoton Gwajin Transfoma Mai Sanya 10kVA Pole6
    Na'urar Canzawa Mai Sanya 15kVA 19.2kV Mai Sanya 19kV
    DL-25/19.92/0.24(0.12), wata na'urar canza wutar lantarki ce ta musamman mai ƙarfin 15 kVA, wacce JZP Transformer ke kera ta da alfahari, kuma tana bin ƙa'idodin IEEE C57.12.20 da ANSI C57.12 masu tsauri. An ƙera wannan na'urar canza wutar lantarki ne don samar da ingantaccen aiki da aminci, tare da biyan buƙatun daban-daban na tsarin rarraba wutar lantarki na zamani. Na'urar canza wutar lantarki ta 15kVA tana da cire polarization kuma tana amfani da ƙungiyar Iio vector, tana tabbatar da ingantaccen kwararar wutar lantarki, da kuma haɓaka aiki da kwanciyar hankali gabaɗaya a cikin hanyar sadarwar rarraba wutar lantarki.
    Rahoton Gwajin Transfoma Mai Sanya 10kVA Pole6
    Rahoton Gwajin Na'urar Canzawa Mai Sanya 10kVA a Pole
    A JZP Transformer, inganci shine kan gaba a tsarin ƙera mu. Kowace transformer da aka ɗora a kan sandar aiki tana fuskantar gwaji mai tsauri da cikakken tsari kafin ta bar masana'antarmu. Muna bin ƙa'idodin kula da inganci masu tsauri don tabbatar da cewa kowace transformer ta cika mafi girman ƙa'idodin masana'antu kuma ta wuce tsammanin abokan ciniki.
    A lokacin gwajin da aka saba yi, ƙwararrun ma'aikatanmu suna duba da kuma tantance aikin na'urar transformer, aminci, da kuma amincinsa sosai. Ana yin cikakken bincike kan muhimman sigogi kamar daidaita ƙarfin lantarki, juriya ga rufin, asarar kaya, rashin kaya, da kuma rashin ƙarfi don tabbatar da ingancin na'urar transformer.
    Sai bayan an yi nasarar cin jarrabawar da aka saba yi kuma aka cika dukkan sharuɗɗan inganci, ana ɗaukar na'urar transformer a matsayin wacce ta cancanci a yi amfani da ita wajen shiryawa da jigilar kaya. Wannan tsari mai kyau yana tabbatar da cewa abokan cinikinmu za su sami na'urorin transformer mafi kyau da inganci waɗanda suka dace da takamaiman buƙatunsu.
    Rahoton Gwajin Transfoma Mai Sanya 10kVA Pole6

    Yi tambaya yanzu!

    Don tambayoyi game da samfuranmu ko mai lissafin farashi, da fatan za a bar mana imel ɗin ku kuma za mu tuntube ku cikin awanni 24.