Na'urar Canzawa Mai Sanya Mataki Guda Ɗaya—37.5 kVA

Matsayin Wutar Lantarki na Farko: 2.4-34.5 kV
Matsayin Wutar Lantarki na Biyu: 120/240V; 240/480V; 347/600Y; 277v;
JERIN TAP NA HV: 2280-36225V
NA'URAR HAƊAWA: Ii0/Ii6
NA'URI: Na Gargajiya/CSP
YAU: 30-150kV
Ma'auni: IEEE C57.12.20, ANSI C57.12, DOE 2016, CSA C2.1&2.2 &CSA C802.1
Aikace-aikace: Rarrabawa, Ayyuka

    Bayanin Samfurin

    JZP babbar masana'antar na'urorin canza wutar lantarki ce da CSA, UL, da cUL suka amince da ita. Sun ƙware wajen samar da na'urorin canza wutar lantarki masu inganci 37.5 kVA guda ɗaya waɗanda suka cika ƙa'idodin ANSI, CSA, IEEE, DOE, da IEC. An tsara waɗannan na'urorin canza wutar lantarki ne don biyan buƙatun aikace-aikace iri-iri, gami da na'urorin samar da wutar lantarki, yankunan karkara, da tsarin rarraba wutar lantarki. Tare da jajircewa mai ƙarfi ga inganci da aminci, na'urorin canza wutar lantarki na JZP an amince da su don ingantaccen aiki da inganci, wanda hakan ya sa suka zama zaɓi mafi kyau ga buƙatu daban-daban da suka shafi wutar lantarki.
    JZP Transformer tana ba da na'urar transformer mai ƙarfin kVA 37.5 mai iya aiki, wadda ta dace da ƙa'idodi daban-daban na duniya, kuma ana iya keɓance ta don dacewa da buƙatu daban-daban. An fitar da na'urorin transformer ɗinmu cikin nasara zuwa ƙasashe da dama, ciki har da Amurka, Kanada, Panama, Venezuela, da Honduras.
    Tare da ƙarfin samarwa na kowane wata na raka'a 500+, muna tabbatar da isar da kayayyaki cikin sauri na makonni 5-8. Alƙawarinmu ga inganci ya wuce masana'antu, domin muna da ƙwararrun ƙungiyoyin shigarwa da gyara bayan siyarwa a Amurka. Wannan yana tabbatar da magance duk wata matsala da za ku iya fuskanta cikin sauri.
    Ko kai kamfanin samar da wutar lantarki ne, ko mai rarraba wutar lantarki, ko kuma mai gini, za ka iya siyan na'urar canza wutar lantarki ta JZP mai matakai ɗaya da kwarin gwiwa, da sanin cewa kana zuba jari a cikin wani samfuri mai inganci da inganci. Ka fuskanci inganci da amincin na'urar canza wutar lantarki ta JZP, wadda aka tsara don biyan buƙatunka na musamman.
    Na'urar Transformer Mai Mataki Ɗaya da Aka Sanya—37
    Na'urar Transfoma 37.5 kVA 13.8 kV
    DL-37.5/13.8/0.24(0.12), na'urar transformer ce mai hawa ɗaya da aka ƙera ta JZP Transformer, wacce aka yi amfani da ita bisa ga ƙa'idodin IEEE da kuma ƙa'idar ingancin DOE 2016. Wannan na'urar transformer tana da ƙarfin 37.5kVA, tare da babban ƙarfin lantarki na 13800V da ƙarancin ƙarfin lantarki na 240 (120) V. Yanayin haɗin sa shine Ii0, yana da ƙirar polarity mai rabewa.
    An ƙera musamman don abokan cinikin Amurka, DL-37.5/13.8/0.24(0.12) yana ba da aiki mai kyau da aminci. Tare da ƙwarewar JZP a ƙira da samar da na'urorin canza wutar lantarki, za ku iya amincewa da na'urar canza wutar lantarki don biyan buƙatunku yadda ya kamata.
    37
    Na'urar Transfoma 14.4 kV 37.5 kVA
    Na'urar canza wutar lantarki ta DL-37.5/14/0.347, ita ce na'urar canza wutar lantarki mai matakai ɗaya da aka ɗora a kan sanda. Wannan na'urar canza wutar lantarki ta cika ƙa'idodin IEEE kuma tana da ƙarfin 37.5 kVA. Tana zuwa da na'urar canza wutar lantarki mai ƙarfi, na'urorin canza wutar lantarki masu ƙarancin wutar lantarki guda biyu, da na'urar canza wutar lantarki mai matsayi 5, wadda ke tabbatar da aiki mai yawa da inganci.
    37
    Na'urar Transfoma 37.5 kVA 19.9 kV
    Na'urar canza wutar lantarki ta DL-37.5/19.9/0.24(0.12), ita ce na'urar canza wutar lantarki mai ƙarfin lantarki. Tare da ƙarfin wutar lantarki mai ƙarfin lantarki na 19920V, tana zuwa da na'urori masu ƙarfin lantarki guda biyu da kuma na'urori masu ƙarancin wutar lantarki guda uku, wanda ke tabbatar da rarraba wutar lantarki ba tare da wata matsala ba.
    Wannan na'urar transformer mai kyau wacce aka ƙera ta da kyau don ingantaccen aiki da aminci mai dorewa. Na'urar transformer ce mai matakai ɗaya mai ƙarfin 37.5kVA wacce aka gina don dacewa da ƙa'idar ANSI C57.12 mai ƙarfi, tana tabbatar da ingantaccen aiki da aminci.