+86 18068001229 01
Na'urar Canza Wutar Lantarki Mai Mataki 3 69kV 4200kVA 5250kVA
Bayanin Samfurin

Na'urorin canza wutar lantarki na 110 kV 115 kV bisa ga ƙa'ida
1. GB 6451 Bayani dalla-dalla da buƙatun fasaha don na'urorin canza wutar lantarki da aka nutsar da mai;
2. Na'urorin Canza Wutar Lantarki na IEC 60076;
3. Na'urorin Canza Wutar Lantarki na AS NZS 60076;
4.CSAC88-16 Transformers na Wutar Lantarki;
5. ANSI/IEEE C57.12.00 Ma'aunin IEEE don Bukatun Gabaɗaya don Rarrabawa, Wutar Lantarki, da Masu Daidaita Na'urorin Canzawa;
6. GOST R 52719 Masu Canza Wutar Lantarki - Bayani na Gabaɗaya;
7. Na'urar Canza Wutar Lantarki ta EN60076;
8. Ayyukan Bayan Siyarwa na Gida A Arewacin Amurka Kudancin Amurka da sauran yankuna suna amsa buƙatunku cikin awanni 24.
Na'urar Canzawa ta 115kV
SF11-20000/115 na'urar canza wutar lantarki ce mai ƙarfin 115 kV 20 MVA, wadda JZP Transformer ke bayarwa. Wannan na'urar canza wutar lantarki tana bin ƙa'idodin samarwa na ANSI C57 Std. Tana da ƙarfin wutar lantarki mai ƙarfi na 115 kV da ƙarancin ƙarfin wutar lantarki na 13.8 kV.
JZP Transformer yana kawo ƙwarewa mai yawa da kuma ingantaccen tarihin ayyukan transformers masu ƙarfin lantarki a cikin kasuwar Amurka. Ƙungiyoyin fasaha da tallace-tallace nasu sun nuna fahimtar ƙa'idodin gida da kuma bin ƙa'idodin ANSI, IEEE, da CSA. Transformers na Daelim Transformer sun sami aikace-aikace masu nasara a cikin shigarwa daban-daban a faɗin Amurka, Kanada, Mexico, Ostiraliya, Ecuador, da sauran ƙasashe.

Fasali na na'urar canza wutar lantarki ta MVA 115 kV 20
Wutar Lantarki: Wannan na'urar transfoma tana aiki a 115 kV kuma tana da ƙarfin wutar lantarki mai yawa na 20 MVA.
Mai Rage Man Fetur: An sanya masa na'urar adana mai domin inganta aiki da kuma tsawon rai.
Alamar Rukunin Vektor: Na'urar transformer tana bin alamar ƙungiyar vektor ta Dyn1.
Hanyoyin Sanyaya: Yana amfani da tsarin sanyaya mai sassauƙa, gami da hanyoyin ONAN, ONAF1, da ONAF2. Ƙimar wutar lantarki ta bambanta a ƙarƙashin waɗannan hanyoyin: 12 MVA don ONAN, 16 MVA don ONAF1, da kuma 20 MVA mai ƙarfi don ONAF2.
Matakan Rufewa: An saita matakin rufin lantarki mai ƙarfi a 550 kV, yayin da matakin rufin ƙasa mai ƙarfi shine 110 kV.
Matsayin Zafin Jiki: An tsara wannan na'urar canza wutar lantarki don ɗaukar matsakaicin hauhawar zafin jiki na 65℃ da matsakaicin hauhawar zafin mai na 55℃.
Mai Canjin Taɓawa: Bangaren HV yana da na'urar canza famfo mai matsayi 5 mai iya aiki, wanda ke ba da damar daidaita ƙarfin lantarki a cikin kewayon ±2×2.5%.
Bushings: Bushings masu ƙarfi da ƙarancin ƙarfin lantarki suna da sauƙin hawa a saman su.
Masu Tara Ruwa: Domin inganta tsaro da kariya, gefen wutar lantarki mai ƙarfi yana da masu tara ruwa guda uku.

Na'urar Canzawa ta 110kV 115kV
An tsara kuma an inganta na'urorin canza wutar lantarki masu ƙarfin 115kV/110kV ta hanyar amfani da fasahohin zamani a cikin gida da waje don inganta tsakiyar na'urar canza wutar lantarki, na'urar sanyaya iska, jiki, jakunkunan wuta, tankin mai, da sauran kayan aiki, waɗanda ke da ƙarancin fitarwa na ɓangare, ƙarancin asara, ƙarancin hayaniya, sauƙi, da kuma babban aminci. Kyakkyawan aikin sa ya sami yabo mai yawa daga masu amfani da ƙwararru masu dacewa. Wannan samfurin yana da halaye na kwanciyar hankali, tattalin arziki, da kariyar muhalli, kuma ya dace da tashoshin wutar lantarki, tashoshin wutar lantarki, manyan masana'antu da kamfanonin hakar ma'adinai, da sauransu.

Gwaji da Cancanta
Na'urar transformer mai karfin 115 kV 20 MVA tana yin gwaje-gwaje masu zurfi domin tabbatar da cewa ta cika ka'idojin da ANSI C57 ta gindaya. Waɗannan gwaje-gwajen sun haɗa da:
Auna Rufewa
Auna Rabon Wutar Lantarki da Rukunin Vector
Auna Sigogi Masu Lanƙwasa
Gwajin Tsarewar Wutar Lantarki Mai Sauri na Tushe daban-daban
Auna Ƙarfin Bushing da Matsayin Dielectric Dissipation Factor
Gwajin Tsayayya da Ƙarfin Wutar Lantarki Mai Ƙarfin Wuta
An haifar da juriya akan wutar lantarki da gwajin fitarwa na wani ɓangare
Ma'aunin Ƙarfin Wutar Lantarki da Asarar Load
Ma'aunin Matakan Hayaniya na Gwajin Impedance Sifili
Gwajin Hatimin Matsi Gwajin Zafin Jiki
Auna Layin Amsawar Mita Mai Juyawa
Gwajin Girman Girman Gwajin Canzawa na Yanzu
Wannan batirin gwaje-gwajen yana tabbatar da cewa na'urar canza wutar lantarki ta 115 kV ta bi ƙa'idodin ANSI C57 kuma ta cancanci cikakkiyar cancanta, wanda ke tabbatar da aminci da aiki.

Bayanin Na'urar Canza Wutar Lantarki ta 110kV da 115kV
| 110kv na'urar canza wutar lantarki mai matakai uku mai duplex mai juyawa akan mai canza kaya | ||||||
| Ƙimar | Haɗin Wutar Lantarki | Babu Rasa Load | Asarar Loda | Babu Load current | Tsarin juriya na gajere | |
| (kVA) | Babban titin HW | LV | ||||
| 6300 kVA | 110kV ±8 | 6.3kv | 10 | 36 | 0.8 | 10.5 |
| 8000 kVA | ×1.25% | 6.6 kW | 12 | 45 | 0.8 | |
| 10000 kVA | 10.5kv | 14.2 | 53 | 0.74 | ||
| 12500 kVA | 115kV ±8 | 11kv | 16.8 | 63 | 0.74 | |
| 16000 kVA | ×1.25% | 20.2 | 77 | 0.69 | ||
| 20000 kVA | 24 | 93 | 0.69 | |||
| 25000 kVA | 28.4 | 110 | 0.64 | |||
| 31500 kVA | 33.8 | 133 | 0.64 | |||
| 40000 kVA | 40.4 | 156 | 0.58 | |||
| 50000 kVA | 47.8 | 194 | 0.58 | |||
| 63000 kVA | 56.8 | 234 | 0.52 | |||
| 110kv na'urar canza wutar lantarki mai matakai uku a kan na'urar canza kaya | ||||||
| Ƙimar | Haɗin Wutar Lantarki | Babu Rasa Load | Asarar Loda | Babu Load current | ||
| (kVA) | HV(kV) | MV(kV) | LV(kV) | |||
| 6300 kVA | 110kv±8 | 35kv | 6.3kv | 12 | 47 | 0.95 |
| 8000 kVA | ×1.25% | 37kv | 6.6 kW | 14.4 | 56 | 0.95 |
| 10 MVA | 38.5kv | 10.5kv | 17.1 | 66 | 0.89 | |
| 12.5 MVA | 115kv±8 | 11kv | 20.2 | 78 | 0.89 | |
| 16MVA | ×1.25% | 24.2 | 95 | 0.84 | ||
| 20MVA | 28.6 | 112 | 0.84 | |||
| 25MVA | 33.8 | 133 | 0.78 | |||
| 31.5MVA | 40.2 | 157 | 0.78 | |||
| 40MVA | 48.2 | 189 | 0.73 | |||
| 50MVA | 56.9 | 225 | 0.73 | |||
| 63MVA | 67.7 | 270 | 0.67 | |||