Leave Your Message

Maganin Canza Wutar Lantarki na Musamman≤2500 kVA

Na'urar canza wutar lantarki muhimmin abu ne a tsarin wutar lantarki, wanda aka tsara don canja wurin wutar lantarki mai canzawa (AC) cikin inganci tsakanin da'irori a matakan ƙarfin lantarki daban-daban. Ya dace da haɓaka ko rage ƙarfin lantarki, waɗannan na'urorin canza wutar lantarki suna tabbatar da ingantaccen rarraba wutar lantarki a cikin hanyoyin samar da wutar lantarki, wuraren masana'antu, da aikace-aikacen kasuwanci. An ƙera na'urorin canza wutar lantarki namu don dorewa da aiki, sun cika ƙa'idodin duniya (IEC, IEEE) yayin da suke ba da fifiko ga aminci, inganci, da dorewa.

    Sigogin samfurin

    Nau'i

    Ƙarfin aiki

    Matsayin Wutar Lantarki

    Sanyaya

    Aikace-aikace

    Na'urar Canza Rarrabawa

    1,600 kVA

    11 kV / 400 V

    MATASA

    Gidaje/masana'antu

    Na'urar Canza Wutar Lantarki

    500 MVA

    220 kV / 33 kV

    OFAF

    Cibiyar watsawa ta yanki

    Mai Canza Na'urar Canja Na UHVDC

    ±400 kV / 500 MVA

    ±800 kV HVDC

    Man fetur da aka tilasta

    Grid na ƙasashen duniya

    Na'urar Canza Gyara

    20 MVA

    33 kV / 1.8 kV × bugun jini 6

    Nau'in busasshe, mai sanyaya iska

    Aluminum electrolysis

    Na'urar Canzawa Mai Nutsewa Mai Yawan Mita 10001 ta CooperNa'urar Canzawa Mai Nutsewa Mai Yawan Mita 10002Na'urar Canzawa Mai Nutsewa Mai Yawan Mita 10003
    Maganin Canza Wutar Lantarki na Musamman≤2500 kVA (1)Maganin Canza Wutar Lantarki na Musamman≤2500 kVA (2)Maganin Canza Wutar Lantarki na Musamman≤2500 kVA (3)Maganin Canza Wutar Lantarki na Musamman≤2500 kVA (4)Maganin Canza Wutar Lantarki na Musamman≤2500 kVA (5)
    • Maganin Canza Wutar Lantarki na Musamman≤2500 kVA (1)
    • Maganin Canza Wutar Lantarki na Musamman≤2500 kVA (2)
    • Maganin Canza Wutar Lantarki na Musamman≤2500 kVA (3)
    • Maganin Canza Wutar Lantarki na Musamman≤2500 kVA (4)
    • Maganin Canza Wutar Lantarki na Musamman≤2500 kVA (5)
    • Maganin Canza Wutar Lantarki na Musamman≤2500 kVA (6)
    Na'urar Transformer Mai Nutsewa a Cikin Mai ta Cooper01

    bayanin samfurin

    1. Ƙarfin da aka ƙima (MVA/kVA)
    Ma'ana: Matsakaicin ƙarfin wutar lantarki mai ci gaba da na'urar transformer zata iya bayarwa.
    Matsakaicin Range:
    Na'urorin Canza Wutar Lantarki: ≤2,500 kVA (misali, rarraba tashar gidaje ko ta masana'antu).
    Na'urorin Canza Wutar Lantarki: Dubban kVA zuwa GVA da yawa (misali, tashoshin watsawa).
    Na'urorin Canza Wutar Lantarki Mai Tsanani (UHV): Don haɗa grid ko amfani da masana'antu, har zuwa ±800 kV na'urorin Canza Wutar Lantarki na HVDC.
    ;2. Matsayin Wutar Lantarki
    Voltage na Input/Fitarwa:
    Babban Wutar Lantarki (HV): Yawanci 33 kV zuwa ±1,100 kV​ (misali, hanyoyin sadarwa na watsawa).
    ​Matsakaicin Wutar Lantarki (MV): Na gama gari ​11 kV, 22 kV, 33 kV.
    Ƙarfin Wutar Lantarki (LV): Yawanci 400 V ko 6.6 kV​ (rarrabawa ga masu amfani).

    Aikace-aikace na Musamman:
    Masu Canza Gyaran Gyara: Don aikin ƙarfe/sunadarai, ƙarfin lantarki har zuwa 30 kV+​.
    Na'urorin Canza Hanya na Layin Jirgin Kasa: An daidaita su don ƙarfin jirgin ƙasa, misali, 27.5 kV ko 1×25 kV.
    ;
    3. Yawan
    Daidaitacce: 50 Hz (China/Turai) ko 60 Hz (Arewacin Amurka).
    Mitoci na Musamman: 400 Hz don aikace-aikacen jiragen sama/na ruwa.
    ;4. Tsarin Sanyaya
    An nutsar da mai:
    ​ONAN​ (Sansanin Iskar Mai ta Halitta): Sanyayawar iska ta halitta.
    ONAF (Mai Amfani da Iska ta Halitta): Sanyaya iska da aka tilasta don inganta aiki.
    Nau'in Busasshe: Sanyaya iska, ya dace da wuraren da ke cikin gida/masu saurin kamuwa da gobara (misali, cibiyoyin bayanai).
    ​Mai Rufe Gas (GIS): Tsarin rufe iskar gas na SF6, ƙaramin tsari don tashoshin da ke da yawan mai.
    ;5. Nau'in Rufi
    Mai da aka nutsar: Man ma'adinai ko man ester (mai kyau ga muhalli).
    Nau'in Busasshe: Simintin resin Epoxy ko kuma rufin takarda na Nomex (wanda ke hana gobara/fashewa).
    Mai Rufe Gas: SF6 ko gaurayen iskar gas (ƙananan tashoshin wutar lantarki masu ƙarfin lantarki mai yawa).
    ;6. Inganci​
    Dabi'u na yau da kullun:
    Transformers na Rarrabawa: ≥98% (ƙarancin rashin kaya da asarar kaya).
    Na'urorin Canza Wutar Lantarki: ≥99% (samfuran ƙarfin lantarki masu matuƙar ƙarfi suna samun ingantaccen aiki).
    Ma'auni: Biye da IEC 61620 ko IEEE C57.12 (misali, buƙatun Ecodesign na EU).
    ;7. Ƙungiyar Haɗi
    Bambancin Mataki: An gano shi azaman Dyn11, Yd11, yana nuna alaƙar mataki tsakanin windings don sarrafa harmonics da currents na gajere.
    ;8. Ƙarfin Inganci
    Ma'ana: Kashi na raguwar ƙarfin lantarki yayin gwajin gajeriyar hanya, yana nuna ƙarfin juriya ga gajeriyar hanya.
    Dabi'un da Aka Saba Amfani da su: 4–10% (masu canza wutar lantarki), ≤4% (masu canza wutar lantarki).
    ;9. Ƙara Zafin Jiki
    Iyaka: Na'urorin canza wutar lantarki da aka nutsar da mai yawanci suna ba da damar ƙaruwar zafin jiki na ≤55 K (man fetur a sama a yanayin zafi na 40°C).
    Daidaita Muhalli: Yankunan hamada suna buƙatar ƙarin tsaftacewa.
    ;10. Ƙimar Kariya
    Lambobin IP:
    IP23: Feshi mai kariya daga ƙura, mai jure ruwa.
    IP66/IP68: An rufe shi gaba ɗaya daga ƙura/ruwa (aikace-aikacen ruwa/na waje).
    Muhalli na Musamman: Feshin gishiri mai jure tsatsa don amfani da bakin teku/ƙasa.
    11. Nau'o'i na Musamman
    Masu Canza Gyaran Gyara: Tsarin bugun jini da yawa (misali, 12/24-pulse) don rage harmonics.
    Transformers Masu Canza Taɓawa: Masu Canza Taɓawa a Kan Lodawa (OLTC) don daidaita ƙarfin lantarki.
    Na'urorin Canzawa na Musamman:
    Na'urorin Canza Wutar Lantarki na Wutar Lantarki: An ƙera su don ɗaukar nauyin da ya wuce kima na ɗan gajeren lokaci (misali, narkar da ƙarfe).
    Masu canza wutar lantarki na Zigzag: Tsarin ƙasa mai tsaka-tsaki don danne wutar lantarki.

    Aikace-aikacen Sanyaya Matsayin Wutar Lantarki Nau'in Ƙarfin Ƙarfi

    Na'urar Canza Rarrabawa 1,600 kVA 11 kV / 400 V ONAN Gidaje/masana'antu
    Na'urar Canza Wutar Lantarki 500 MVA 220 kV / 33 kV OFAF Cibiyar watsawa ta yanki
    Mai Canza Canjin UHVDC ±400 kV / 500 MVA ±800 kV HVDC Man fetur mai tilastawa a tsakanin nahiyoyi
    Na'urar Canza Gyara 20 MVA 33 kV / 1.8 kV × 6-pulse Busasshe, mai sanyaya iska, aluminum electrolysis
    Na'urar Transformer Mai Nutsewa a Cikin Mai ta Cooper02Na'urar Transformer Mai Nutsewa a Cikin Mai ta Cooper03Na'urar Transformer Mai Nutsewa a Cikin Mai ta Cooper04Na'urar Transformer Mai Nutsewa a Cikin Mai ta Cooper05

    Me yasa za mu zaɓa

    An kafa JIEZOU POWER a shekarar 1989, ƙwararren mai ƙira, mai ƙera da kuma mai saka tsarin wutar lantarki a faɗin duniya.
    JIEZOU POWER, galibi tana kula da ayyukan layin wutar lantarki, 500KV EPC, tashar wutar lantarki ta hydroelectric 230KV, tashar wutar lantarki ta 115KV, da sauransu.
    Masana'antar JIEZOU POWER na iya kera na'urar canza wutar lantarki ta nau'in mai da busasshiyar na'ura, matsakaicin na'urar canza wutar lantarki ta 500KV 480MVA, GIS, switchgear, da kuma tashar substation, bisa ga ma'aunin ANSI/IEEE/DOE2016/CSA/IEC60076.
    JIEZOU POWER ta samu takardar shaidar ISO9001, ISO14001, ISO45001, UL, CUL, CSA, SGS, TUV, INTERTEK, da kuma rahoton gwajin nau'in. Har zuwa shekarar 2023, ana rarraba kamfanoni da masana'antu na duniya a Amurka, Kanada, Dubai, Jamhuriyar Dominican, Philippines, masana'antu da kamfanoni na reshe na kasar Sin suna cikin birnin BengBu, birnin FengYang, birnin HaiAn, birnin TaiZhou, birnin SuZhou, birnin ShenYang, da kuma birnin FoShan.
    Idan aka yi la'akari da makomar, hangen nesa na JIEZOU POWER shine a zama mai samar da mafita ga tsarin wutar lantarki mafi aminci, a magance ƙalubalen sarrafa wutar lantarki mafi gaggawa a duniya, a hanzarta sauye-sauyen duniya zuwa makamashi mai sabuntawa. Domin kowa ya sami rayuwa mai ƙarancin carbon da haske. Don haka, za mu yi iya ƙoƙarinmu don yin ƙoƙari.
    Na'urar Transformer Mai Nutsewa a Cikin Mai ta Cooper06Na'urar Transformer Mai Nutsewa a Cikin Mai ta Cooper07Na'urar Transformer Mai Nutsewa a Cikin Mai ta Cooper08Na'urar Transformer Mai Nutsewa a Cikin Mai ta Cooper09

    Yi tambaya yanzu!

    Don tambayoyi game da samfuranmu ko mai lissafin farashi, da fatan za a bar mana imel ɗin ku kuma za mu tuntube ku cikin awanni 24.

    Leave Your Message