Leave Your Message

Na'urorin Canza Mai Masu Inganci 220kVA Don Amfani Mai Nauyi

Na'urar Transformer Mai Nutsewa ta 220kVA, na'urar rarraba wutar lantarki ce mai inganci kuma mai inganci wadda aka ƙera don aikace-aikacen masana'antu, kasuwanci, da kayayyakin more rayuwa. Tana amfani da man ma'adinai ko man rufewa mai kyau ga muhalli don sanyaya, wanda hakan ke ba da damar canza wutar lantarki mai karko (misali, 10kV zuwa 0.4kV). An gina ta da kayan aiki masu ƙarfi da fasaha ta zamani, tana ba da tsawon rai, ƙarancin kulawa, da kuma daidaitawa ga yanayi mai tsauri.

    Siffofin Tsarin

    Core
    Rigunan ƙarfe na silicon masu sanyi da aka yi birgima da su masu ƙarfi da rufin Layer don rage asarar wutar lantarki.
    Tsarin sassa biyar mai matakai uku don rage juriyar sifili da kuma danne jituwa.
    ;Windings
    Babban Na'urar Rage Wutar Lantarki: Rage murfin tagulla tare da rufin Nomex na takarda mai layi biyu.
    Ƙarfin Ƙarfin Wutar Lantarki: Tsarin silinda mai launuka da yawa don haɓaka juriya ga gajerun da'ira.
    ;Tanki da Sanyaya
    Tsarin ONAN tare da zagayawa na mai na halitta kuma babu fanfunan waje, ya dace da shigarwa a waje.
    An haɗa fikafikan radiator na corrugated a cikin tanki don ingantaccen watsa zafi.
    ;Tsarin Rufewa
    Man ma'adinai (ko man ester mai kyau ga muhalli) yana samar da rufin rufi, sanyaya, da kuma karewa daga lalacewa.
    Matakin fitarwa na wani ɓangare ≤50pC (IEC 60076 ta yi daidai).
    Na'urar Canzawa Mai Nutsewa Mai Yawan Mita 10001 ta CooperNa'urar Canzawa Mai Nutsewa Mai Yawan Mita 10002Na'urar Canzawa Mai Nutsewa Mai Yawan Mita 10003
    Core
    • Na'urorin Canza Man Fetur Masu Inganci 220kVA Don Amfani Mai Nauyi (1)
    • Na'urorin Canza Mai Masu Inganci 220kVA Don Amfani Mai Nauyi (2)
    • Na'urorin Canza Man Fetur Masu Inganci 220kVA Don Amfani Mai Nauyi (3)
    • Na'urorin Canza Man Fetur Masu Inganci 220kVA Don Amfani Mai Nauyi (4)
    • Na'urorin Canza Man Fetur Masu Inganci 220kVA Don Amfani Mai Nauyi (5)
    • Na'urorin Canza Man Fetur Masu Inganci 220kVA Don Amfani Mai Nauyi (6)
    Na'urar Transformer Mai Nutsewa a Cikin Mai ta Cooper01

    Aikace-aikace

    Rarraba Wutar Lantarki ta Masana'antu
    Rarraba matsakaicin ƙarfin lantarki (10kV zuwa 0.4kV) a masana'antu, ma'adanai, da masana'antun ƙarfe.
    Yana tallafawa ɗaukar nauyi na ɗan gajeren lokaci (misali, tanderun lantarki, sabbin motoci).
    ;Gine-ginen Kasuwanci
    Rarraba wutar lantarki ga manyan kantuna, hasumiyoyin ofisoshi, da otal-otal.
    ;Kayayyakin more rayuwa
    Tashoshin jiragen ƙasa, filayen jirgin sama, da kuma wuraren tace ruwan shara.
    ;Yankuna Masu Nisa
    Yana aiki yadda ya kamata a yanayin zafi mai yawa, ƙura, ko yanayin zafi mai canzawa.

    Muhimman Fa'idodi

    Babban Aminci
    Tankin da aka rufe gaba ɗaya yana hana iskar shaka da gurɓata mai.
    Ƙarfin juriya na gajere (mai bin ƙa'idar GB/T 1094.5).
    ;Ƙarancin Kulawa
    Tsarin da ba shi da kulawa tare da matakin mai da kuma sa ido kan zafin jiki na ainihin lokaci.
    ;Mai Inganci da Farashi
    Ƙarancin jarin farko da ƙarancin asarar makamashin aiki.
    ;Zaɓuɓɓukan Masu Amfani da Muhalli
    Ana samunsa tare da man ester mai lalacewa (misali, FR3) don bin ƙa'idodin RoHS.

    Ka'idojin Zaɓe

    Kowace na'ura tana fuskantar gwaji mai tsauri, gami da:
    Gwaje-gwajen juriyar rufi da gwajin ƙarfin lantarki.
    Ma'aunin asarar kaya da asarar kaya ba tare da wani nauyi ba.
    Tabbatar da juriya ga gajere.
    An ba da takardar shaidar ISO 9001, ISO 14001, da KEMA don bin ƙa'idodin duniya.

    Ka'idojin Zaɓe

    Siffofin Load
    Tabbatar da nau'in kaya (mai dorewa ko mai canzawa).
    Kimanta buƙatun ɗaukar kaya na ɗan gajeren lokaci (misali, tanderun lantarki).
    ;Yanayin Muhalli
    Tsawon ≤ mita 1,000 (ana buƙatar cirewa sama da wannan).
    Zafin yanayi: -25℃ zuwa +45℃ (ingantaccen sanyaya ga yankuna masu zafi).
    ;Biyayya
    Ya cika ka'idojin GB 1094 (China), IEC 60076 (na ƙasashen duniya), da takaddun shaida na musamman ga masana'antu (misali, ATEX don yanayin fashewa).

    Shigarwa da Gyara

    Bukatun Shigarwa
    Tushen tushe mai matakin tare da izinin ≥1m a kowane gefe don watsa zafi.
    Juriyar ƙasa ≤4Ω; ƙirar kariya ta walƙiya daban.
    ;Kulawa ta yau da kullun
    A duba matakin mai, launinsa, da kuma ɗigon ruwa duk bayan wata shida.
    Gwada juriyar rufin gida kowace shekara ta amfani da na'urar auna ƙarfin lantarki ta 2,500V.
    ;Shirya matsala
    Dumama fiye da kima: Duba toshewar radiator ko kuma lodin da ba su dace ba.
    Binciken Tsarin Chromatography na Mai: Gano alamun farko na fitar da ruwa daga ciki ko lalacewar rufin.
    Na'urar Transformer Mai Nutsewa a Cikin Mai ta Cooper02Na'urar Transformer Mai Nutsewa a Cikin Mai ta Cooper03Na'urar Transformer Mai Nutsewa a Cikin Mai ta Cooper04Na'urar Transformer Mai Nutsewa a Cikin Mai ta Cooper05

    Me yasa za mu zaɓa

    An kafa JIEZOU POWER a shekarar 1989, ƙwararren mai ƙira, mai ƙera da kuma mai saka tsarin wutar lantarki a faɗin duniya.
    JIEZOU POWER, galibi tana kula da ayyukan layin wutar lantarki, 500KV EPC, tashar wutar lantarki ta hydroelectric 230KV, tashar wutar lantarki ta 115KV, da sauransu.
    Masana'antar JIEZOU POWER na iya kera na'urar canza wutar lantarki ta nau'in mai da busasshiyar na'ura, matsakaicin na'urar canza wutar lantarki ta 500KV 480MVA, GIS, switchgear, da kuma tashar substation, bisa ga ma'aunin ANSI/IEEE/DOE2016/CSA/IEC60076.
    JIEZOU POWER ta samu takardar shaidar ISO9001, ISO14001, ISO45001, UL, CUL, CSA, SGS, TUV, INTERTEK, da kuma rahoton gwajin nau'in. Har zuwa shekarar 2023, ana rarraba kamfanoni da masana'antu na duniya a Amurka, Kanada, Dubai, Jamhuriyar Dominican, Philippines, masana'antu da kamfanoni na reshe na kasar Sin suna cikin birnin BengBu, birnin FengYang, birnin HaiAn, birnin TaiZhou, birnin SuZhou, birnin ShenYang, da kuma birnin FoShan.
    Idan aka yi la'akari da makomar, hangen nesa na JIEZOU POWER shine a zama mai samar da mafita ga tsarin wutar lantarki mafi aminci, a magance ƙalubalen sarrafa wutar lantarki mafi gaggawa a duniya, a hanzarta sauye-sauyen duniya zuwa makamashi mai sabuntawa. Domin kowa ya sami rayuwa mai ƙarancin carbon da haske. Don haka, za mu yi iya ƙoƙarinmu don yin ƙoƙari.
    Na'urar Transformer Mai Nutsewa a Cikin Mai ta Cooper06Na'urar Transformer Mai Nutsewa a Cikin Mai ta Cooper07Na'urar Transformer Mai Nutsewa a Cikin Mai ta Cooper08Na'urar Transformer Mai Nutsewa a Cikin Mai ta Cooper09

    Yi tambaya yanzu!

    Don tambayoyi game da samfuranmu ko mai lissafin farashi, da fatan za a bar mana imel ɗin ku kuma za mu tuntube ku cikin awanni 24.

    Leave Your Message